Vitros Systems (2014-04-11)
- Starting date:
- April 11, 2014
- Posting date:
- May 5, 2014
- Type of communication:
- Medical Device Recall
- Subcategory:
- Medical Device
- Hazard classification:
- Type III
- Source of recall:
- Health Canada
- Issue:
- Medical Devices
- Audience:
- General Public, Healthcare Professionals, Hospitals
- Identification number:
- RA-39319
Recalled Products
A. Vitros Chemistry Products 5.1 FS Chemistry System - Analyzer
B. Vitros Chemistry Products 5.1 FS Chemistry System - Refurbished
C. Vitros Chemistry Products 5.1 FS Chemistry System - Instrument
D. Vitros 5600 Integrated System - Instrument
E. Vitros 5600 Integrated System
F. Vitros 4600 Chemistry System - Hardware
Reason
OCD has issued a recall due to the potential for biased results when a multiple window (MW) code is associated with results generated by the Vitros 5600 Integrated system, Vitros 4600 Chemistry system and Vitros 5.1 Chemistry system. MW codes may be associated with results from any of the following Vitros Chemistry products using multiple point (Multipoint) rate measurements: Alt slides, ALKP slides, AST slides, CHE slides, CK slides, GGT slides, LDH slides. Multipoint rate assays measure enzyme activity via multiple readings which are used to generate a kinetic curve and calculate results. The MW algorithm assesses the validity of the kinetic curve. An MW code is generated if a single point exceeds predetermined limits, provided that all surrounding values are within acceptable limits.
Affected products
A. Vitros Chemistry Products 5.1 FS Chemistry System - Analyzer
Lot or serial number
More than 10 numbers, contact manufacturer
Model or catalog number
6801375
Companies
- Manufacturer
-
Ortho-Clinical Diagnostics, Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
B. Vitros Chemistry Products 5.1 FS Chemistry System - Refurbished
Lot or serial number
More than 10 numbers, contact manufacturer
Model or catalog number
6801890
Companies
- Manufacturer
-
Ortho-Clinical Diagnostics, Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
C. Vitros Chemistry Products 5.1 FS Chemistry System - Instrument
Lot or serial number
More than 10 numbers, contact manufacturer
Model or catalog number
6801375
Companies
- Manufacturer
-
Ortho-Clinical Diagnostics, Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
D. Vitros 5600 Integrated System - Instrument
Lot or serial number
More than 10 numbers, contact manufacturer
Model or catalog number
680 2413
Companies
- Manufacturer
-
Ortho-Clinical Diagnostics, Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
E. Vitros 5600 Integrated System
Lot or serial number
More than 10 numbers, contact manufacturer
Model or catalog number
680 2413
Companies
- Manufacturer
-
Ortho-Clinical Diagnostics, Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES
F. Vitros 4600 Chemistry System - Hardware
Lot or serial number
More than 10 numbers, contact manufacturer
Model or catalog number
680 2445
Companies
- Manufacturer
-
Ortho-Clinical Diagnostics, Inc.
100 Indigo Creek Drive
Rochester
14626
New York
UNITED STATES