Vitros Chemistry Systems (2015-04-07)
- Starting date:
- April 7, 2015
- Posting date:
- April 30, 2015
- Type of communication:
- Medical Device Recall
- Subcategory:
- Medical Device
- Hazard classification:
- Type II
- Source of recall:
- Health Canada
- Issue:
- Medical Devices
- Audience:
- General Public, Healthcare Professionals, Hospitals
- Identification number:
- RA-53179
Recalled Products
A. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #66236)
B. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #66236, REFURBISHED)
C. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #67361)
D. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #67361, REFURBISHED)
E. VITROS 5600 INTEGRATED SYSTEM (DEVICE LICENCE #78571)
F. VITROS 5600 INTEGRATED SYSTEM (DEVICE LICENCE #80701)
G. VITROS 4600 CHEMISTRY SYSTEM (DEVICE LICENCE #85176 AND #86236)
Reason
Ortho-Clinical Diagnostics, Inc. (OCD) has confirmed instances where the Vitros system allowed urine samples for assays that required acidified pretreatment to be metered from the same sample container as assays that required no pretreatment when the sample was programmed. This has been attributed to a software anomaly. Depending upon the assay, urine samples either need to be acidified, alkalized or require no pretreatment. The anomaly occurs when manually programming urine samples or using a downloaded sample program from a laboratory information system (LIS) and the sample program contains assays requiring sample pretreatment and assays requiring no sample pretreatment. if this anomaly occurs, it is possible for Vitros 5,1, 4600 or 5600 systems to process urine samples without the proper pretreatment, potentially leading to biased patient results.
Affected products
A. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #66236)
Lot or serial number
More than 10 numbers, contact manufacturer.
Model or catalog number
6801375
6801890
Companies
- Manufacturer
-
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
B. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #66236, REFURBISHED)
Lot or serial number
More than 10 numbers, contact manufacturer.
Model or catalog number
6801375
6801890
Companies
- Manufacturer
-
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
C. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #67361)
Lot or serial number
More than 10 numbers, contact manufacturer.
Model or catalog number
6801375
6801890
Companies
- Manufacturer
-
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
D. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #67361, REFURBISHED)
Lot or serial number
More than 10 numbers, contact manufacturer.
Model or catalog number
6801375
6801890
Companies
- Manufacturer
-
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
E. VITROS 5600 INTEGRATED SYSTEM (DEVICE LICENCE #78571)
Lot or serial number
More than 10 numbers, contact manufacturer.
Model or catalog number
6802413
Companies
- Manufacturer
-
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
F. VITROS 5600 INTEGRATED SYSTEM (DEVICE LICENCE #80701)
Lot or serial number
More than 10 numbers, contact manufacturer.
Model or catalog number
6802413
Companies
- Manufacturer
-
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES
G. VITROS 4600 CHEMISTRY SYSTEM (DEVICE LICENCE #85176 AND #86236)
Lot or serial number
More than 10 numbers, contact manufacturer.
Model or catalog number
6802445
Companies
- Manufacturer
-
Ortho-clinical Diagnostics Inc.
100 Indigo Creek Drive
Rochester
14626
UNITED STATES