This page has been archived on the Web

Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject to the Government of Canada Web Standards and has not been altered or updated since it was archived. Please contact us to request a format other than those available.

Health product recall

Vitros Chemistry Systems (2015-04-07)

Starting date:
April 7, 2015
Posting date:
April 30, 2015
Type of communication:
Medical Device Recall
Subcategory:
Medical Device
Hazard classification:
Type II
Source of recall:
Health Canada
Issue:
Medical Devices
Audience:
General Public, Healthcare Professionals, Hospitals
Identification number:
RA-53179

Recalled Products

A. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #66236)

B. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #66236, REFURBISHED)

C. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #67361)

D. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #67361, REFURBISHED)

E. VITROS 5600 INTEGRATED SYSTEM (DEVICE LICENCE #78571)

F. VITROS 5600 INTEGRATED SYSTEM (DEVICE LICENCE #80701)

G. VITROS 4600 CHEMISTRY SYSTEM (DEVICE LICENCE #85176 AND #86236)

Reason

Ortho-Clinical Diagnostics, Inc. (OCD) has confirmed instances where the Vitros system allowed urine samples for assays that required acidified pretreatment to be metered from the same sample container as assays that required no pretreatment when the sample was programmed. This has been attributed to a software anomaly. Depending upon the assay, urine samples either need to be acidified, alkalized or require no pretreatment. The anomaly occurs when manually programming urine samples or using a downloaded sample program from a laboratory information system (LIS) and the sample program contains assays requiring sample pretreatment and assays requiring no sample pretreatment. if this anomaly occurs, it is possible for Vitros 5,1, 4600 or 5600 systems to process urine samples without the proper pretreatment, potentially leading to biased patient results.

Affected products

A. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #66236)

Lot or serial number

More than 10 numbers, contact manufacturer.

Model or catalog number

6801375

6801890

Companies
Manufacturer

Ortho-clinical Diagnostics Inc.

100 Indigo Creek Drive

Rochester

14626

UNITED STATES



B. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #66236, REFURBISHED)

Lot or serial number

More than 10 numbers, contact manufacturer.

Model or catalog number

6801375

6801890

Companies
Manufacturer

Ortho-clinical Diagnostics Inc.

100 Indigo Creek Drive

Rochester

14626

UNITED STATES



C. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #67361)

Lot or serial number

More than 10 numbers, contact manufacturer.

Model or catalog number

6801375

6801890

Companies
Manufacturer

Ortho-clinical Diagnostics Inc.

100 Indigo Creek Drive

Rochester

14626

UNITED STATES



D. VITROS 5,1 FS CHEMISTRY (DEVICE LICENCE #67361, REFURBISHED)

Lot or serial number

More than 10 numbers, contact manufacturer.

Model or catalog number

6801375

6801890

Companies
Manufacturer

Ortho-clinical Diagnostics Inc.

100 Indigo Creek Drive

Rochester

14626

UNITED STATES



E. VITROS 5600 INTEGRATED SYSTEM (DEVICE LICENCE #78571)

Lot or serial number

More than 10 numbers, contact manufacturer.

Model or catalog number

6802413

Companies
Manufacturer

Ortho-clinical Diagnostics Inc.

100 Indigo Creek Drive

Rochester

14626

UNITED STATES



F. VITROS 5600 INTEGRATED SYSTEM (DEVICE LICENCE #80701)

Lot or serial number

More than 10 numbers, contact manufacturer.

Model or catalog number

6802413

Companies
Manufacturer

Ortho-clinical Diagnostics Inc.

100 Indigo Creek Drive

Rochester

14626

UNITED STATES



G. VITROS 4600 CHEMISTRY SYSTEM (DEVICE LICENCE #85176 AND #86236)

Lot or serial number

More than 10 numbers, contact manufacturer.

Model or catalog number

6802445

Companies
Manufacturer

Ortho-clinical Diagnostics Inc.

100 Indigo Creek Drive

Rochester

14626

UNITED STATES