Health product recall

UNICEL Immunoassay System, Ostate Assay, Calibrators and QC (2016-10-25)

Starting date:
October 25, 2016
Posting date:
November 9, 2016
Type of communication:
Medical Device Recall
Subcategory:
Medical Device
Hazard classification:
Type II
Source of recall:
Health Canada
Issue:
Medical Devices
Audience:
General Public, Healthcare Professionals, Hospitals
Identification number:
RA-60952

Affected Products

A. UNICEL DXI 600 ACCESS IMMUNOASSAY SYSTEM - OSTASE ASSAY

B. ACCESS SYSTEM - OSTASE ASSAY

C. UNICEL DXI 800 ACCESS IMMUNOASSAY SYSTEM - OSTASE ASSAY

D. ACCESS OSTASE CALIBRATORS

E. ACCESS OSTASE QC

Reason

Beckman Coulter has determined that specific Access Ostase Calibrator and QC lots do not meet their expiration date claims within our 10% criteria. For these lots we determined that REF B83876 and B83877 have 68 days of stability and REF 37305 and 37309 have 51 days of stability.

Access Ostase Calibrator and QC instability could result in falsely elevated patient results or QC failures.

For 37305/37309, the instability could cause patient results to be overestimated by as much as 16% at the original expiration dates.

For B83876/B83877, the instability could cause patient results to be overestimated by as much as 16% as of October 17, 2016.

Affected products

A. UNICEL DXI 600 ACCESS IMMUNOASSAY SYSTEM - OSTASE ASSAY

Lot or serial number

628294

628296

628297

Model or catalog number

37305

37309

Companies
Manufacturer

Beckman Coulter Inc.

250 S. Kraemer Blvd.

Brea

92821

California

UNITED STATES



B. ACCESS SYSTEM - OSTASE ASSAY

Lot or serial number

628294

628296

628297

Model or catalog number

37305

37309

Companies
Manufacturer

Beckman Coulter Inc.

250 S. Kraemer Blvd.

Brea

92821

California

UNITED STATES



C. UNICEL DXI 800 ACCESS IMMUNOASSAY SYSTEM - OSTASE ASSAY

Lot or serial number

628294

628296

628297

Model or catalog number

37305

37309

Companies
Manufacturer

Beckman Coulter Inc.

250 S. Kraemer Blvd.

Brea

92821

California

UNITED STATES



D. ACCESS OSTASE CALIBRATORS

Lot or serial number

623207

626000

Model or catalog number

B83876

Companies
Manufacturer

Beckman Coulter Inc.

250 S. Kraemer Blvd.

Brea

92821

California

UNITED STATES



E. ACCESS OSTASE QC

Lot or serial number

623208

626001

Model or catalog number

B83877

Companies
Manufacturer

Beckman Coulter Inc.

250 S. Kraemer Blvd.

Brea

92821

California

UNITED STATES