Vehicle recall

Transport Canada Recall - 2010368 - WINNEBAGO INDUSTRIES

Brand(s)
Last updated

Summary

Product
Motorhome recalled by WINNEBAGO INDUSTRIES
Issue
Vehicle - Accessories
What to do

Please see corrective actions section below

Affected products

1996 | ITASCA | ELLIPSE, 1996 | ITASCA | HORIZON, 1996 | ITASCA | MERIDIAN, 1996 | ITASCA | SUNCRUISER, 1996 | ITASCA | SUNFLYER, 1996 | ITASCA | SUNOVA, 1996 | ITASCA | SUNRISE, 1996 | ITASCA | SUNSTAR, 1996 | WINNEBAGO | ADVENTURER, 1996 | WINNEBAGO | BRAVE, 1996 | WINNEBAGO | CHIEFTAIN, 1996 | WINNEBAGO | JOURNEY, 1996 | WINNEBAGO | JOURNEY DL, 1996 | WINNEBAGO | LUXOR, 1996 | WINNEBAGO | SIGHTSEER, 1996 | WINNEBAGO | TOUR, 1996 | WINNEBAGO | ULTIMATE ADVANTAGE, 1996 | WINNEBAGO | ULTIMATE FREEDOM, 1996 | WINNEBAGO | VECTRA, 1996 | WINNEBAGO | VECTRA GRAND TOUR, 1996 | WINNEBAGO | VISTA, 1997 | ITASCA | ELLIPSE, 1997 | ITASCA | HORIZON, 1997 | ITASCA | MERIDIAN, 1997 | ITASCA | SUNCRUISER, 1997 | ITASCA | SUNFLYER, 1997 | ITASCA | SUNOVA, 1997 | ITASCA | SUNRISE, 1997 | ITASCA | SUNSTAR, 1997 | WINNEBAGO | ADVENTURER, 1997 | WINNEBAGO | BRAVE, 1997 | WINNEBAGO | CHIEFTAIN, 1997 | WINNEBAGO | JOURNEY, 1997 | WINNEBAGO | JOURNEY DL, 1997 | WINNEBAGO | LUXOR, 1997 | WINNEBAGO | SIGHTSEER, 1997 | WINNEBAGO | TOUR, 1997 | WINNEBAGO | ULTIMATE ADVANTAGE, 1997 | WINNEBAGO | ULTIMATE FREEDOM, 1997 | WINNEBAGO | VECTRA, 1997 | WINNEBAGO | VECTRA GRAND TOUR, 1997 | WINNEBAGO | VISTA, 1998 | ITASCA | ELLIPSE, 1998 | ITASCA | HORIZON, 1998 | ITASCA | MERIDIAN, 1998 | ITASCA | SUNCRUISER, 1998 | ITASCA | SUNFLYER, 1998 | ITASCA | SUNOVA, 1998 | ITASCA | SUNRISE, 1998 | ITASCA | SUNSTAR, 1998 | WINNEBAGO | ADVENTURER, 1998 | WINNEBAGO | BRAVE, 1998 | WINNEBAGO | CHIEFTAIN, 1998 | WINNEBAGO | JOURNEY, 1998 | WINNEBAGO | JOURNEY DL, 1998 | WINNEBAGO | LUXOR, 1998 | WINNEBAGO | SIGHTSEER, 1998 | WINNEBAGO | TOUR, 1998 | WINNEBAGO | ULTIMATE ADVANTAGE, 1998 | WINNEBAGO | ULTIMATE FREEDOM, 1998 | WINNEBAGO | VECTRA, 1998 | WINNEBAGO | VECTRA GRAND TOUR, 1998 | WINNEBAGO | VISTA, 1999 | ITASCA | ELLIPSE, 1999 | ITASCA | HORIZON, 1999 | ITASCA | MERIDIAN, 1999 | ITASCA | SUNCRUISER, 1999 | ITASCA | SUNFLYER, 1999 | ITASCA | SUNOVA, 1999 | ITASCA | SUNRISE, 1999 | ITASCA | SUNSTAR, 1999 | WINNEBAGO | ADVENTURER, 1999 | WINNEBAGO | BRAVE, 1999 | WINNEBAGO | CHIEFTAIN, 1999 | WINNEBAGO | JOURNEY, 1999 | WINNEBAGO | JOURNEY DL, 1999 | WINNEBAGO | LUXOR, 1999 | WINNEBAGO | SIGHTSEER, 1999 | WINNEBAGO | TOUR, 1999 | WINNEBAGO | ULTIMATE ADVANTAGE, 1999 | WINNEBAGO | ULTIMATE FREEDOM, 1999 | WINNEBAGO | VECTRA, 1999 | WINNEBAGO | VECTRA GRAND TOUR, 1999 | WINNEBAGO | VISTA, 2000 | ITASCA | ELLIPSE, 2000 | ITASCA | HORIZON, 2000 | ITASCA | MERIDIAN, 2000 | ITASCA | SUNCRUISER, 2000 | ITASCA | SUNFLYER, 2000 | ITASCA | SUNOVA, 2000 | ITASCA | SUNRISE, 2000 | ITASCA | SUNSTAR, 2000 | WINNEBAGO | ADVENTURER, 2000 | WINNEBAGO | BRAVE, 2000 | WINNEBAGO | CHIEFTAIN, 2000 | WINNEBAGO | JOURNEY, 2000 | WINNEBAGO | JOURNEY DL, 2000 | WINNEBAGO | LUXOR, 2000 | WINNEBAGO | SIGHTSEER, 2000 | WINNEBAGO | TOUR, 2000 | WINNEBAGO | ULTIMATE ADVANTAGE, 2000 | WINNEBAGO | ULTIMATE FREEDOM, 2000 | WINNEBAGO | VECTRA, 2000 | WINNEBAGO | VECTRA GRAND TOUR, 2000 | WINNEBAGO | VISTA, 2001 | ITASCA | ELLIPSE, 2001 | ITASCA | HORIZON, 2001 | ITASCA | MERIDIAN, 2001 | ITASCA | SUNCRUISER, 2001 | ITASCA | SUNFLYER, 2001 | ITASCA | SUNOVA, 2001 | ITASCA | SUNRISE, 2001 | ITASCA | SUNSTAR, 2001 | WINNEBAGO | ADVENTURER, 2001 | WINNEBAGO | BRAVE, 2001 | WINNEBAGO | CHIEFTAIN, 2001 | WINNEBAGO | JOURNEY, 2001 | WINNEBAGO | JOURNEY DL, 2001 | WINNEBAGO | LUXOR, 2001 | WINNEBAGO | SIGHTSEER, 2001 | WINNEBAGO | TOUR, 2001 | WINNEBAGO | ULTIMATE ADVANTAGE, 2001 | WINNEBAGO | ULTIMATE FREEDOM, 2001 | WINNEBAGO | VECTRA, 2001 | WINNEBAGO | VECTRA GRAND TOUR, 2001 | WINNEBAGO | VISTA, 2002 | ITASCA | ELLIPSE, 2002 | ITASCA | HORIZON, 2002 | ITASCA | MERIDIAN, 2002 | ITASCA | SUNCRUISER, 2002 | ITASCA | SUNFLYER, 2002 | ITASCA | SUNOVA, 2002 | ITASCA | SUNRISE, 2002 | ITASCA | SUNSTAR, 2002 | WINNEBAGO | ADVENTURER, 2002 | WINNEBAGO | BRAVE, 2002 | WINNEBAGO | CHIEFTAIN, 2002 | WINNEBAGO | JOURNEY, 2002 | WINNEBAGO | JOURNEY DL, 2002 | WINNEBAGO | LUXOR, 2002 | WINNEBAGO | SIGHTSEER, 2002 | WINNEBAGO | TOUR, 2002 | WINNEBAGO | ULTIMATE ADVANTAGE, 2002 | WINNEBAGO | ULTIMATE FREEDOM, 2002 | WINNEBAGO | VECTRA, 2002 | WINNEBAGO | VECTRA GRAND TOUR, 2002 | WINNEBAGO | VISTA, 2003 | ITASCA | ELLIPSE, 2003 | ITASCA | HORIZON, 2003 | ITASCA | MERIDIAN, 2003 | ITASCA | SUNCRUISER, 2003 | ITASCA | SUNFLYER, 2003 | ITASCA | SUNOVA, 2003 | ITASCA | SUNRISE, 2003 | ITASCA | SUNSTAR, 2003 | WINNEBAGO | ADVENTURER, 2003 | WINNEBAGO | BRAVE, 2003 | WINNEBAGO | CHIEFTAIN, 2003 | WINNEBAGO | JOURNEY, 2003 | WINNEBAGO | JOURNEY DL, 2003 | WINNEBAGO | LUXOR, 2003 | WINNEBAGO | SIGHTSEER, 2003 | WINNEBAGO | TOUR, 2003 | WINNEBAGO | ULTIMATE ADVANTAGE, 2003 | WINNEBAGO | ULTIMATE FREEDOM, 2003 | WINNEBAGO | VECTRA, 2003 | WINNEBAGO | VECTRA GRAND TOUR, 2003 | WINNEBAGO | VISTA, 2004 | ITASCA | ELLIPSE, 2004 | ITASCA | HORIZON, 2004 | ITASCA | MERIDIAN, 2004 | ITASCA | SUNCRUISER, 2004 | ITASCA | SUNFLYER, 2004 | ITASCA | SUNOVA, 2004 | ITASCA | SUNRISE, 2004 | ITASCA | SUNSTAR, 2004 | WINNEBAGO | ADVENTURER, 2004 | WINNEBAGO | BRAVE, 2004 | WINNEBAGO | CHIEFTAIN, 2004 | WINNEBAGO | JOURNEY, 2004 | WINNEBAGO | JOURNEY DL, 2004 | WINNEBAGO | LUXOR, 2004 | WINNEBAGO | SIGHTSEER, 2004 | WINNEBAGO | TOUR, 2004 | WINNEBAGO | ULTIMATE ADVANTAGE, 2004 | WINNEBAGO | ULTIMATE FREEDOM, 2004 | WINNEBAGO | VECTRA, 2004 | WINNEBAGO | VECTRA GRAND TOUR, 2004 | WINNEBAGO | VISTA, 2005 | ITASCA | ELLIPSE, 2005 | ITASCA | HORIZON, 2005 | ITASCA | MERIDIAN, 2005 | ITASCA | SUNCRUISER, 2005 | ITASCA | SUNFLYER, 2005 | ITASCA | SUNOVA, 2005 | ITASCA | SUNRISE, 2005 | ITASCA | SUNSTAR, 2005 | WINNEBAGO | ADVENTURER, 2005 | WINNEBAGO | BRAVE, 2005 | WINNEBAGO | CHIEFTAIN, 2005 | WINNEBAGO | JOURNEY, 2005 | WINNEBAGO | JOURNEY DL, 2005 | WINNEBAGO | LUXOR, 2005 | WINNEBAGO | SIGHTSEER, 2005 | WINNEBAGO | TOUR, 2005 | WINNEBAGO | ULTIMATE ADVANTAGE, 2005 | WINNEBAGO | ULTIMATE FREEDOM, 2005 | WINNEBAGO | VECTRA, 2005 | WINNEBAGO | VECTRA GRAND TOUR, 2005 | WINNEBAGO | VISTA, 2006 | ITASCA | ELLIPSE, 2006 | ITASCA | HORIZON, 2006 | ITASCA | MERIDIAN, 2006 | ITASCA | SUNCRUISER, 2006 | ITASCA | SUNFLYER, 2006 | ITASCA | SUNOVA, 2006 | ITASCA | SUNRISE, 2006 | ITASCA | SUNSTAR, 2006 | WINNEBAGO | ADVENTURER, 2006 | WINNEBAGO | BRAVE, 2006 | WINNEBAGO | CHIEFTAIN, 2006 | WINNEBAGO | JOURNEY, 2006 | WINNEBAGO | JOURNEY DL, 2006 | WINNEBAGO | LUXOR, 2006 | WINNEBAGO | SIGHTSEER, 2006 | WINNEBAGO | TOUR, 2006 | WINNEBAGO | ULTIMATE ADVANTAGE, 2006 | WINNEBAGO | ULTIMATE FREEDOM, 2006 | WINNEBAGO | VECTRA, 2006 | WINNEBAGO | VECTRA GRAND TOUR, 2006 | WINNEBAGO | VISTA, 2007 | ITASCA | ELLIPSE, 2007 | ITASCA | HORIZON, 2007 | ITASCA | MERIDIAN, 2007 | ITASCA | SUNCRUISER, 2007 | ITASCA | SUNFLYER, 2007 | ITASCA | SUNOVA, 2007 | ITASCA | SUNRISE, 2007 | ITASCA | SUNSTAR, 2007 | WINNEBAGO | ADVENTURER, 2007 | WINNEBAGO | BRAVE, 2007 | WINNEBAGO | CHIEFTAIN, 2007 | WINNEBAGO | JOURNEY, 2007 | WINNEBAGO | JOURNEY DL, 2007 | WINNEBAGO | LUXOR, 2007 | WINNEBAGO | SIGHTSEER, 2007 | WINNEBAGO | TOUR, 2007 | WINNEBAGO | ULTIMATE ADVANTAGE, 2007 | WINNEBAGO | ULTIMATE FREEDOM, 2007 | WINNEBAGO | VECTRA, 2007 | WINNEBAGO | VECTRA GRAND TOUR, 2007 | WINNEBAGO | VISTA, 2008 | ITASCA | ELLIPSE, 2008 | ITASCA | HORIZON, 2008 | ITASCA | MERIDIAN, 2008 | ITASCA | SUNCRUISER, 2008 | ITASCA | SUNFLYER, 2008 | ITASCA | SUNOVA, 2008 | ITASCA | SUNRISE, 2008 | ITASCA | SUNSTAR, 2008 | WINNEBAGO | ADVENTURER, 2008 | WINNEBAGO | BRAVE, 2008 | WINNEBAGO | CHIEFTAIN, 2008 | WINNEBAGO | JOURNEY, 2008 | WINNEBAGO | JOURNEY DL, 2008 | WINNEBAGO | LUXOR, 2008 | WINNEBAGO | SIGHTSEER, 2008 | WINNEBAGO | TOUR, 2008 | WINNEBAGO | ULTIMATE ADVANTAGE, 2008 | WINNEBAGO | ULTIMATE FREEDOM, 2008 | WINNEBAGO | VECTRA, 2008 | WINNEBAGO | VECTRA GRAND TOUR, 2008 | WINNEBAGO | VISTA, 2009 | ITASCA | ELLIPSE, 2009 | ITASCA | HORIZON, 2009 | ITASCA | MERIDIAN, 2009 | ITASCA | SUNCRUISER, 2009 | ITASCA | SUNFLYER, 2009 | ITASCA | SUNOVA, 2009 | ITASCA | SUNRISE, 2009 | ITASCA | SUNSTAR, 2009 | WINNEBAGO | ADVENTURER, 2009 | WINNEBAGO | BRAVE, 2009 | WINNEBAGO | CHIEFTAIN, 2009 | WINNEBAGO | JOURNEY, 2009 | WINNEBAGO | JOURNEY DL, 2009 | WINNEBAGO | LUXOR, 2009 | WINNEBAGO | SIGHTSEER, 2009 | WINNEBAGO | TOUR, 2009 | WINNEBAGO | ULTIMATE ADVANTAGE, 2009 | WINNEBAGO | ULTIMATE FREEDOM, 2009 | WINNEBAGO | VECTRA, 2009 | WINNEBAGO | VECTRA GRAND TOUR, 2009 | WINNEBAGO | VISTA, 2010 | ITASCA | ELLIPSE, 2010 | ITASCA | HORIZON, 2010 | ITASCA | MERIDIAN, 2010 | ITASCA | SUNCRUISER, 2010 | ITASCA | SUNFLYER, 2010 | ITASCA | SUNOVA, 2010 | ITASCA | SUNRISE, 2010 | ITASCA | SUNSTAR, 2010 | WINNEBAGO | ADVENTURER, 2010 | WINNEBAGO | BRAVE, 2010 | WINNEBAGO | CHIEFTAIN, 2010 | WINNEBAGO | JOURNEY, 2010 | WINNEBAGO | JOURNEY DL, 2010 | WINNEBAGO | LUXOR, 2010 | WINNEBAGO | SIGHTSEER, 2010 | WINNEBAGO | TOUR, 2010 | WINNEBAGO | ULTIMATE ADVANTAGE, 2010 | WINNEBAGO | ULTIMATE FREEDOM, 2010 | WINNEBAGO | VECTRA, 2010 | WINNEBAGO | VECTRA GRAND TOUR, 2010 | WINNEBAGO | VISTA, 2011 | ITASCA | ELLIPSE, 2011 | ITASCA | HORIZON, 2011 | ITASCA | MERIDIAN, 2011 | ITASCA | SUNCRUISER, 2011 | ITASCA | SUNFLYER, 2011 | ITASCA | SUNOVA, 2011 | ITASCA | SUNRISE, 2011 | ITASCA | SUNSTAR, 2011 | WINNEBAGO | ADVENTURER, 2011 | WINNEBAGO | BRAVE, 2011 | WINNEBAGO | CHIEFTAIN, 2011 | WINNEBAGO | JOURNEY, 2011 | WINNEBAGO | JOURNEY DL, 2011 | WINNEBAGO | LUXOR, 2011 | WINNEBAGO | SIGHTSEER, 2011 | WINNEBAGO | TOUR, 2011 | WINNEBAGO | ULTIMATE ADVANTAGE, 2011 | WINNEBAGO | ULTIMATE FREEDOM, 2011 | WINNEBAGO | VECTRA, 2011 | WINNEBAGO | VECTRA GRAND TOUR, 2011 | WINNEBAGO | VISTA

Issue

Certain refrigerators used in Recreational Vehicles (RVs) contain either a sensing algorithm or a thermal switch to interrupt power when it detects high temperatures that could lead to a fire. An insufficient response time can result in the power not being shut-off in sufficient time to prevent a fire, which could result in property damage and/or personal injury. Correction: Dealers will install a thermocouple with a faster response time for all refrigerators with a sensing algorithm or a thermal switch.

Additional information

Background

Visit Transport Canada’s Motor Vehicle Safety Recalls Database for the original recall.

Details
Original published date:
Alert / recall type
Vehicle recall
Category
Vehicles - Motorhome
Companies
Published by
Transport Canada
Audience
General public
Identification number
RA-71614
Transport Canada ID
2010368

Get notified

Receive emails about new and updated recall and safety alerts.

Subscribe