This page has been archived on the Web

Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject to the Government of Canada Web Standards and has not been altered or updated since it was archived. Please contact us to request a format other than those available.

Health professional risk communication

Potential Effect of DEPO-PROVERA (medroxyprogesterone acetate injectable suspension, USP) on Bone Mineral Density changes in adults and adolescents - Pfizer Canada Inc.

Starting date:
June 30, 2005
Posting date:
July 7, 2005
Type of communication:
Dear Healthcare Professional Letter
Subcategory:
Drugs, Affects children, pregnant or breast feeding women
Source of recall:
Health Canada
Audience:
Healthcare Professionals
Identification number:
RA-17000990

This is duplicated text of a letter from Pfizer Canada Inc.

Contact the company for a copy of any references, attachments or enclosures.

Notice about Health Canada advisories

[Text of letter begins]

Health Canada Endorsed Important Safety Information on DEPO-PROVERA (medroxyprogesterone acetate)

June 30, 2005

Subject: Important Safety Update: Potential effect of DEPO-PROVERA* (medroxyprogesterone acetate injectable suspension, USP) on Bone Mineral Density (BMD) changes in adults and adolescents

Dear Health Care Professional,

Pfizer Canada Inc. in consultation with Health Canada, would like to inform you of important updated safety information and upcoming changes to the Product Monograph for DEPO-PROVERA (medroxyprogesterone acetate injectable suspension, USP), indicated for conception control (prevention of pregnancy), treatment of endometriosis, adjunctive and/or palliative treatment of recurrent and/or metastatic endometrial or renal cell carcinoma (hypernephroid carcinomas) and adjunctive or palliative treatment of hormonally-dependent, recurrent, inoperable or metastatic carcinoma of the breast in post-menopausal women.

As a result of new clinical studies, one with premenopausal adult women (age 25-35 years) and one with adolescent women (age 12-18 years) using DEPO-PROVERA 150 mg IM for contraception, we now have data regarding the use of DEPO-PROVERA and its associated effect on bone mineral density (BMD). The data indicate that women who use DEPO-PROVERA may lose significant BMD. The data also indicate that bone loss is greater with increasing duration of use and may not be completely reversible. The DEPO-PROVERA Product Monograph has been revised to include the following new information in addition to a summary of the available data:

Boxed WARNINGS

  • The use of DEPO-PROVERA has been associated with loss of bone mineral density (BMD) which may not be completely reversible. Loss of bone mineral density is greater with increasing duration of use.
  • It is unknown if use of DEPO-PROVERA during adolescence or early adulthood, a critical period of bone accretion, will reduce peak bone mass and increase the risk for osteoporotic fracture in later life.
  • DEPO-PROVERA should be used as a birth control method or endometriosis treatment only if other treatments have been considered to be unsuitable or unacceptable, and should be used for the shortest period of time possible. The risks and benefits of treatment should be carefully re-evaluated on a regular basis in all users of the drug.

INDICATIONS and CLINICAL USE

  • Although there are no studies addressing whether calcium and vitamin D may lessen BMD loss in women using DEPO-PROVERA, all patients should have adequate calcium and vitamin D intake. Cessation of smoking and regular weight bearing exercise should be discussed with all patients.

CONTRAINDICATIONS

  • DEPO-PROVERA should not be used before menarche.

WARNINGS

Loss of Bone Mineral Density

Contraception/Endometriosis

  • Use of DEPO-PROVERA should be considered a risk factor for osteoporosis. The use of DEPO-PROVERA should be considered in light of a patient's possible other risk factors for osteoporosis (including metabolic bone disease, chronic alcohol and/or tobacco use, anorexia nervosa, strong family history of osteoporosis or chronic use of drugs that can reduce bone mass such as anticonvulsants or corticosteroids).
  • BMD should be monitored in women using DEPO-PROVERA for longer than 2 years, or earlier as clinically appropriate. In adolescent females, interpretation of BMD results should take into account patient age and skeletal maturity. If a clinically significant decrease in BMD is detected, treatment with DEPO-PROVERA should be reconsidered.

Oncology

  • There are no studies on the effects of the high doses of parenteral medroxyprogesterone acetate (e.g. for oncology use). If a patient is using DEPO-PROVERA as part of adjunctive or palliative treatment of endometrial, renal cell or breast carcinoma, evaluation of BMD is recommended as deemed clinically appropriate.

Post-marketing experience

  • In post-marketing experience, there have been cases of osteoporosis including osteoporotic fractures reported in patients taking DEPO-PROVERA. Patient age ranged from 16 years to 48 years.

INFORMATION FOR THE CONSUMER

Will be updated to reflect the above new information.

We trust this information is useful in providing guidance on the appropriate use of DEPO-PROVERA.

Pfizer Canada Inc. is committed to providing you with the most current product safety information on its products and routinely assesses safety information and updates Product Monographs accordingly.

Reporting rates determined on the basis of spontaneously reported post-marketing adverse events are generally presumed to underestimate the risks associated with drug treatments.

The identification, characterization, and management of marketed health product-related adverse reactions are dependent on the active participation of health care professionals in adverse drug reaction reporting programmes. Any occurrences of osteopenia, osteoporosis, fracture or other serious and/or unexpected adverse reactions in patients receiving DEPO-PROVERA (medroxyprogesterone acetate injectable suspension, USP) should be reported to Pfizer Canada Inc. and/or Health Canada at the following addresses:

Pfizer Canada Inc.

Safety and Medical Information

P.O. Box 800

Pointe-Claire, Quebec

H9R 4V2

1-800-463-6001

Any suspected adverse reaction can also be reported to:

Canadian Adverse Drug Reaction Monitoring Program (CADRMP)

Marketed Health Products Directorate

HEALTH CANADA

Address Locator: 0701C

OTTAWA, Ontario, K1A 0K9

Tel: 613-957-0337 or Fax: 613-957-0335

To report an Adverse Reaction, consumers and health professionals may call toll free:

Tel: 1-866-234-2345

Fax: 1-866-678-6789

cadrmp@hc-sc.gc.ca

For other inquiries, please refer to contact information:

Bureau of Metabolism, Oncology and Reproductive Sciences (BMORS)

BMORS_Enquiries@hc-sc.gc.ca

Telephone: 613-941-3171

Fax: 613-941-1365

The AR Reporting Form and the AR Guidelines can be found on the Health Canada web site or in The Canadian Compendium of Pharmaceuticals and Specialties.

Sincerely,

original signed by

Bernard Prigent, M.D., M.B.A.

Vice President & Medical Director

Pfizer Canada Inc.

* TM Pfizer Enterprises, SARL, Pfizer Canada Inc. Licensee

[Text of letter ends]