Health product recall

MULTIDIAGNOST ELEVA, OMINIDOIAGNOST ELEVA, ALLURA XPER VARIOUS MODELS

Starting date:
August 16, 2016
Type of communication:
Medical Device Recall
Subcategory:
Medical Device
Hazard classification:
Type II
Source of recall:
Health Canada
Issue:
Medical Devices
Audience:
General Public, Healthcare Professionals, Hospitals
Identification number:
RA-60066

Affected Products

  1. MULTIDIAGNOST ELEVA - IMAGE INTENSIFIER - TV IMAGE DETECTOR
  2. MULTIDIAGNOST ELEVA - FLAT DETECTOR - IMAGE DETECTOR
  3. ALLURA XPER FD10/10 - MAIN UNIT
  4. ALLURA XPER FD20/10 SYSTEM - MAIN UNIT
  5. ALLURA XPER FD20/20
  6. OMNIDIAGNOST ELEVA
  7. ALLURA XPER FD10
  8. ALLURA XPER FD20 SYSTEM - MAIN UNIT
  9. ALLURA XPER FD20 OR TABLE

Reason

Philips Healthcare has discovered through customer feedback, a system restart failure as a result of a blown fuse. The fuse was blown due to an unexpected main power failure in the hospital in which the uninterruptible power supply (UPS) took over.

Philips discovered after internal investigation that in time the fuse degrades.

The degrading depends on the initial value of the fuse, the current through the fuse, a continuous high operating temperature, the environmental temperature and the time the system is operational.

After degradation, the blowing of the fuse may be triggered by an unexpected main power failure as described above.

Affected products

A. MULTIDIAGNOST ELEVA - IMAGE INTENSIFIER - TV IMAGE DETECTOR

Lot or serial number

More than 10 numbers, contact manufacturer.

Model or catalog number

0708MD02

Companies
Manufacturer

Philips Medical Systems Nederland B.V.

Veenpluis 4-6

Best

5684

NETHERLANDS



B. MULTIDIAGNOST ELEVA - FLAT DETECTOR - IMAGE DETECTOR

Lot or serial number

More than 10 numbers, contact manufacturer.

Model or catalog number

0708MD02

Companies
Manufacturer

Philips Medical Systems Nederland B.V.

Veenpluis 4-6

Best

5684

NETHERLANDS



C. ALLURA XPER FD10/10 - MAIN UNIT

Lot or serial number

154

215

306

307

40

405

449

489

Model or catalog number

ALLURA XPER FD10/10

Companies
Manufacturer

Philips Medical Systems Nederland B.V.

Veenpluis 4-6

Best

5684

NETHERLANDS



D. ALLURA XPER FD20/10 SYSTEM - MAIN UNIT

 

Lot or serial number

168

283

37

52

567

57

 

Model or catalog number

ALLURA XPER FD20/10

Companies
Manufacturer

Philips Medical Systems Nederland B.V.

Veenpluis 4-6

Best

5684

NETHERLANDS



E. ALLURA XPER FD20/20

Lot or serial number

171

607

Model or catalog number

ALLURA XPER FD20/20

Companies
Manufacturer

Philips Medical Systems Nederland B.V.

Veenpluis 4-6

Best

5684

NETHERLANDS



F. OMNIDIAGNOST ELEVA

Lot or serial number

More than 10 numbers, contact manufacturer.

 

Model or catalog number

708027

Companies
Manufacturer

Philips Medical Systems Nederland B.V.

Veenpluis 4-6

Best

5684

NETHERLANDS



G. ALLURA XPER FD10

Lot or serial number

More than 10 numbers, contact manufacturer.

Model or catalog number

ALLURA XPER FD10

Companies
Manufacturer

Philips Medical Systems Nederland B.V.

Veenpluis 4-6

Best

5684

NETHERLANDS



H. ALLURA XPER FD20 SYSTEM - MAIN UNIT

Lot or serial number

More than 10 numbers, contact manufacturer.

Model or catalog number

ALLURA XPER FD20

Companies
Manufacturer

Philips Medical Systems Nederland B.V.

Veenpluis 4-6

Best

5684

NETHERLANDS



I. ALLURA XPER FD20 OR TABLE

Lot or serial number

146,33

Model or catalog number

454

Companies
Manufacturer

Philips Medical Systems Nederland B.V.

Veenpluis 4-6

Best

5684

NETHERLANDS