This page has been archived on the Web

Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject to the Government of Canada Web Standards and has not been altered or updated since it was archived. Please contact us to request a format other than those available.

Health product recall

Dimension Systems-Ammonia Assays (2017-03-07)

Starting date:
March 7, 2017
Posting date:
March 24, 2017
Type of communication:
Medical Device Recall
Subcategory:
Medical Device
Hazard classification:
Type III
Source of recall:
Health Canada
Issue:
Medical Devices
Audience:
General Public, Healthcare Professionals, Hospitals
Identification number:
RA-62788

Affected Products

A. Dimension Exl System-Ammonia (Amm) Assay

B. Dimension Xpand System-Ammonia (Amm) Assay

C. Dimension Exl System-Ammonia (Amm) Assay

Reason

In September 2014, Siemens Healthcare Diagnostics issued customer notification 14-62 that addressed a high rate of "abnormal assay" test report messages for its Dimension Ammonia (AMM) Assay. With this letter, Siemens is reducing the AMM open well stability from 3 days to 1 day (24 hours) and providing instructions for managing this change. Dimension AMM instructions for use (IFU) revision E will reflect this change.

The new version of dimension software, 10.2, will do the following: 

  • automatically move to a new well every day. This decrease in the open well maximum duration reduces the amount of time the AMM reagent is exposed to any potential contaminates, reduces the need for customers to manually move to a new reagent well, and aids in the prevention of erroneous flagging.
  • contain the below mean factor limit of 0.90.

Siemens is working to make Dimension Software10.2 available to all customers as quickly as possible.

Affected products

A. Dimension Exl System-Ammonia (Amm) Assay

Lot or serial number

All lots

Model or catalog number

10711991

DF119

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Delaware

UNITED STATES



B. Dimension Xpand System-Ammonia (Amm) Assay

Lot or serial number

All lots

Model or catalog number

10711991

DF119

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Delaware

UNITED STATES



C. Dimension Exl System-Ammonia (Amm) Assay

Lot or serial number

All lots

Model or catalog number

10711991

DF119

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Delaware

UNITED STATES