This page has been archived on the Web
Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject to the Government of Canada Web Standards and has not been altered or updated since it was archived. Please contact us to request a format other than those available.
Brilliance Products
- Starting date:
- December 19, 2012
- Posting date:
- January 21, 2013
- Type of communication:
- Medical Device Recall
- Subcategory:
- Medical Device
- Hazard classification:
- Type II
- Source of recall:
- Health Canada
- Issue:
- Medical Devices
- Audience:
- General Public, Healthcare Professionals, Hospitals
- Identification number:
- RA-16831
Recalled Products
- Brilliance Computed Tomography System – (6,10, 16, Slice)
- Brilliance 40/64 Slice CT System
- Brilliance CT Big Bore System – Main Unit
- Brilliance 64 Slice CT System – Main Unit
- Brilliance ICT System – System
- Brilliance Computed Tomography System
- Brilliance ICT SP System – Main
Reason
Philips Healthcare has received reports from the field stating the patient table on a system had an unexpected downward movement while a patient was on the table. Philips has determined that the cause was a malfunction of the vertical brake of the patient support due to embrittlement of the vertical brake's screws.
Affected products
A. Brilliance Computed Tomography System – (6,10, 16, Slice)
Lot or serial number
More than 10 Numbers, Contact manufacturer
Model or catalog number
4535 670 73181, 4535 670 73191
Companies
- Manufacturer
-
Philips Medical Systems (Cleveland) Inc.
B. Brilliance 40/64 Slice CT System
Lot or serial number
More than 10 Numbers, Contact manufacturer
Model or catalog number
4550 11004011
Companies
- Manufacturer
-
Philips Medical Systems (Cleveland) Inc.
C. Brilliance CT Big Bore System – Main Unit
Lot or serial number
More than 10 Numbers, Contact manufacturer
Model or catalog number
4535 670 88051
Companies
- Manufacturer
-
Philips Medical Systems (Cleveland) Inc.
D. Brilliance 64 Slice CT System – Main Unit
Lot or serial number
More than 10 Numbers, Contact manufacturer
Model or catalog number
4550 110 00921
Companies
- Manufacturer
-
Philips Medical Systems (Cleveland) Inc.
E. Brilliance ICT System – System
Lot or serial number
More than 10 Numbers, Contact manufacturer
Model or catalog number
728306
Companies
- Manufacturer
-
Philips Medical Systems (Cleveland) Inc.
F. Brilliance Computed Tomography System
Lot or serial number
More than 10 Numbers, Contact manufacturer
Model or catalog number
453567005721
Companies
- Manufacturer
-
Philips Medical Systems (Cleveland) Inc.
G. Brilliance ICT SP System – Main
Lot or serial number
More than 10 Numbers, Contact manufacturer
Model or catalog number
728311
Companies
- Manufacturer
-
Philips Medical Systems (Cleveland) Inc.