Health product recall

Brightview Gamma, XCT, and X Camera Systems (2013-12-24)

Starting date:
December 24, 2013
Posting date:
January 24, 2014
Type of communication:
Medical Device Recall
Subcategory:
Medical Device
Hazard classification:
Type II
Source of recall:
Health Canada
Issue:
Medical Devices
Audience:
General Public, Healthcare Professionals, Hospitals
Identification number:
RA-37643

Recalled products

  1. Brightview Gamma Camera System with 3/8 inch Crystal
  2. Brightview Gamma Camera System with 3/8 inch Crystal and Detector Caudal Cephalic Tilt
  3. Brightview XCT Imaging System - Tilt System
  4. Brightview X System with 3/8 inch Crystal (Upgradeable Version)

Reason

Philips has become aware of several software issues which will be corrected with the release of a new software version.

Problem 1: When positioning for a relative 180 degree non circular acquisition the second (bottom) detector was not positioned correctly by an operator, causing an inappropriate rotation orbit calculation for the patient being imaged. When the acquisition was started and the detectors began to move into position, the incorrect calculation resulted in the detectors coming in contact with the patient.

Problem 2: On separate occasions, as the gantry system was moving to a relative 90 scan position of the detectors, a patient or operator moved their hands or arms into the path of the detectors in the area of where the detectors meet resulting in the detectors coming in contact with the patient and operator.

Problem 3: While a user was manually positioning the patient for their exam and translating the pallet into the gantry bore, the pallet catcher that supports the imaging table was higher than the imaging pallet resulting in a pinch point or table tilt if not engaged with the catcher. This problem can only occur on the Brightview X or the Brightview XCT system.

Affected products

A. Brightview Gamma Camera System with 3/8 inch Crystal

Lot or serial number

All lots

Model or catalog number
  • 2170-3000A
Companies
Manufacturer
Philips Medical Systems (Cleveland), Inc.
595 Miner Road
Cleveland
44143
Ohio
UNITED STATES

B. Brightview Gamma Camera System with 3/8 inch Crystal and Detector Caudal Cephalic Tilt

Lot or serial number

All lots

Model or catalog number
  • 2170-3002A
Companies
Manufacturer
Philips Medical Systems (Cleveland), Inc.
595 Miner Road
Cleveland
44143
Ohio
UNITED STATES

C. Brightview XCT Imaging System - Tilt System

Lot or serial number

All lots

Model or catalog number
  • 453560462131
  • 453560749161
Companies
Manufacturer
Philips Medical Systems (Cleveland), Inc.
595 Miner Road
Cleveland
44143
Ohio
UNITED STATES

D. Brightview X System with 3/8 inch Crystal (Upgradeable Version)

Lot or serial number

All lots

Model or catalog number
  • 453560829241
Companies
Manufacturer
Philips Medical Systems (Cleveland), Inc.
595 Miner Road
Cleveland
44143
Ohio
UNITED STATES