This page has been archived on the Web

Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject to the Government of Canada Web Standards and has not been altered or updated since it was archived. Please contact us to request a format other than those available.

Health professional risk communication

Archived - Important Safety Concerns re Use of Propofol for Sedation in Pediatric Patients

Starting date:
May 1, 2001
Posting date:
May 1, 2001
Type of communication:
Notice to Hospitals
Subcategory:
Drugs, Affects children, pregnant or breast feeding women
Source of recall:
Health Canada
Audience:
Hospitals
Identification number:
RA-17000220

Notice about Health Canada advisories

[Text of letter begins]

Important Safety Concerns re Use of PROPOFOL for sedation in pediatric patients

May 1, 2001

To: Hospital Chief of Medical Staff

Please forward the following information to involved professional staff in Departments such as Pharmacy, Intensive Care Units (ICUs) and Anaesthesiology.

The Canadian approved Product Monograph states in the INDICATIONS section: "Propofol is not recommended for sedation in children under the age of 18, either during surgical / diagnostic procedures or in the Intensive Care Unit (ICU), as safety and efficacy have not been established."

Health Canada is re-emphasizing the importance of strict adherence to the current Canadian approved Product Monograph. This recommendation is based on newly-obtained clinical trial information reviewed by the U.S. FDA

Therapeutic Products Directorate (TPD) wishes to draw your attention to a warning letter addressed to Health Professionals in the U.S. regarding important safety concerns when propofol is used for sedation in the ICU in pediatric patients. This letter was posted on the Food and Drug Administration (FDA) web site on April 25, 2001. http://www.fda.gov/medwatch/safety/2001/diprivan_deardoc.pdf

[Text of letter begins]

March 26,2001

Dear Health Care Provider,

I am writing to inform you that based on a recent review of new clinical trial data, the Food and Drug Administration (FDA) has determined that there may be important safety concerns when propofol, marketed by AstraZeneca as DIPRIVAN (propofol) Injectable Emulsion, is used for sedation in the Intensive Care Unit (ICU) in pediatric patients. I would like to remind you that propofol is not approved in the US for sedation in pediatric ICU patients and should not be used for this purpose.

The FDA's determination was made based on the review of data from a randomized, controlled, clinical trial that evaluated the safety and effectiveness of DIPRIVAN versus standard sedative agents (SSA) in pediatric ICU patients. In that study a total of 327 pediatric patients were randomized to receive either DIPRIVAN 2% (113 patients), DIPRIVAN 1% (109 patients),or an SSA (eg, lorazepam, chloral hydrate, fentanyl, ketamine, morphine, or phenobarbital). DIPRIVAN therapy was initiated at an infusion rate of 5.5 mg/kg/hr and titrated as needed to maintain sedation at a standardized level. The results of the study showed an increase in the number of deaths in patients treated with DIPRIVAN as compared to SSAs. A total of 25 patients died during the trial or within the 28-day follow-up period:12 (11%) in the DIPRIVAN 2%treatment group, 9 (8%) in the DIPRIVAN 1%treatment group, and 4 (4%) in the SSA treatment group. In the opinion of FDA, careful review of the deaths failed to reveal a correlation with underlying disease status, nor did the review reveal a definite pattern to the causes of death. In order to better understand this potential safety issue AstraZeneca will initiate a new clinical trial designed specifically to evaluate any differences in adverse events and deaths in pediatric patients randomized to propofol or SSAs for ICU sedation. If you would like additional information related to the trial, please call the AstraZeneca Information Center. Sincerely,

We would like to reemphasize that propofol is currently not approved for sedation in pediatric ICU patients in the US and should not be used for this purpose. It is important that you forward any adverse event information involving propofol to AstraZeneca (for DIPRIVAN) at the Information Center 1-800-236-9933,8 am -7 pm or to the FDA via the MedWatch system. Copies of the MedWatch form are available on the FDA web site (http://www.fda.gov/medwatch/index.html or http://www.fda.gov/medwatch/safety.htm) as listed.

David Goodale, DDS, PhD

Medical Leader for Pain,Anesthesia and Infection Products

AstraZeneca LP

Enclosure

AstraZeneca Pharmaceuticals LP Tel 302 886 3000

1800 Concord Pike PO Box 15437 Wilmington DE 19850-5437 www.astrazeneca-us.com

[Text of letter ends]

Questions regarding this message can be directed to the Central Nervous System Unit, Bureau of Pharmaceutical Assessment, Therapeutic Products Directorate at: (613) 941-3181

Any suspected adverse drug reactions can be reported to:

Canadian Adverse Reaction Monitoring Program (CADRMP)

Bureau of Licensed Product Assessment

Therapeutic Products Directorate

Health Canada

Address Locator: 0201C2

Ottawa, Ontario, K1A 1B9

Tel: (613) 957-0337 or Fax: (613) 957-0335

cadrmp@hc-sc.gc.ca

The ADR Reporting Form can be found in The Canadian Compendium of Pharmaceutical and Specialties, or on the TPD website, along with the ADR Guidelines.

[Text of letter ends]