Advia Centaur System - Instruments
- Starting date:
- November 8, 2012
- Posting date:
- December 10, 2012
- Type of communication:
- Medical Device Recall
- Subcategory:
- Medical Device
- Hazard classification:
- Type III
- Source of recall:
- Health Canada
- Issue:
- Medical Devices
- Audience:
- General Public (GP), Healthcare Professionals, Hospitals
- Identification number:
- RA-16321
Recalled Products
- Advia Centaur System - Instrument Class 3
- Advia Centaur XP System - Instrument Class 2
- Advia Centaur XP System - Instrument Class IV
- Advia Centaur XP System - Instrument Class III
- Advia Centaur System - Instrument Class II
- Advia Centaur System - Instrument Class IV
Reason
The wash interconnect circuit board on the Advia Centaur / Advia Centaur XP can fail due to contamination on the board during manufacturing and/or during use. When a failure occurs, it is possible to have incorrect reporting of the wash1 sensors status. The fluid line of either sensor (S1 or S2) is reported to be empty when it is actually full, or reported to be full when it is empty. These failures could either lead to the system not detecting an empty wash1 bottle or reservoir, or stop the system from running due to a supposedly empty wash1 reservoir. If the sensors both fail in the "wet" state due to the board malfunction, an erroneous but believable result may be released to the physician which is falsely high or low (depending on the assay architecture - Competitive or Sandwich).
Affected products
A. Advia Centaur System - Instrument Class 3
Lot or serial number
More than 10 Numbers, contact manufacturer
Model or catalog number
04911855, 078-A001-14
Companies
- Manufacturer
-
Siemens Healthcare Diagnostics Inc.
B. Advia Centaur XP System - Instrument Class 2
Lot or serial number
More than 10 Numbers, contact manufacturer
Model or catalog number
078-A010-07, 09066916
Companies
- Manufacturer
-
Siemens Healthcare Diagnostics Inc.
C. Advia Centaur XP System - Instrument Class IV
Lot or serial number
More than 10 numbers, contact manufacturer
Model or catalog number
078-A010-07, 09066916
Companies
- Manufacturer
-
Siemens Healthcare Diagnostics Inc.
D. Advia Centaur XP System - Instrument Class III
Lot or serial number
More than 10 numbers, contact manufacturer
Model or catalog number
078-A010-07, 09066916
Companies
- Manufacturer
-
Siemens Healthcare Diagnostics Inc.
E. Advia Centaur System - Instrument Class II
Lot or serial number
More than 10 numbers, contact manufacturer
Model or catalog number
04911855, 078-A001-14
Companies
- Manufacturer
-
Siemens Healthcare Diagnostics Inc.
F. Advia Centaur System - Instrument Class IV
Lot or serial number
More than 10 numbers, contact manufacturer
Model or catalog number
04911855, 078-A001-14
Companies
- Manufacturer
-
Siemens Healthcare Diagnostics Inc.