Numéro de rappel de Transports Canada - 2020430 -
Marque(s)
Résumé
Veuillez consulter la section des mesures correctives ci-dessous
Produits visés
1995 | HOLDER | SERIES L, 1995 | HOLDER | SERIES V, 1995 | HOLDER | SERIES M, 1995 | HOLDER | MUVO, 1995 | HOLDER | SERIES A, 1995 | HOLDER | SERIES F, 1995 | HOLDER | SERIES B, 1995 | HOLDER | SERIES S, 1995 | HOLDER | SERIES C, 1996 | HOLDER | SERIES F, 1996 | HOLDER | SERIES B, 1996 | HOLDER | SERIES V, 1996 | HOLDER | SERIES M, 1996 | HOLDER | MUVO, 1996 | HOLDER | SERIES C, 1996 | HOLDER | SERIES S, 1996 | HOLDER | SERIES A, 1996 | HOLDER | SERIES L, 1997 | HOLDER | MUVO, 1997 | HOLDER | SERIES F, 1997 | HOLDER | SERIES C, 1997 | HOLDER | SERIES B, 1997 | HOLDER | SERIES A, 1997 | HOLDER | SERIES S, 1997 | HOLDER | SERIES L, 1997 | HOLDER | SERIES M, 1997 | HOLDER | SERIES V, 1998 | HOLDER | SERIES C, 1998 | HOLDER | SERIES S, 1998 | HOLDER | SERIES M, 1998 | HOLDER | SERIES A, 1998 | HOLDER | SERIES B, 1998 | HOLDER | SERIES L, 1998 | HOLDER | SERIES F, 1998 | HOLDER | MUVO, 1998 | HOLDER | SERIES V, 1999 | HOLDER | SERIES V, 1999 | HOLDER | SERIES B, 1999 | HOLDER | SERIES S, 1999 | HOLDER | SERIES M, 1999 | HOLDER | SERIES F, 1999 | HOLDER | SERIES A, 1999 | HOLDER | SERIES C, 1999 | HOLDER | SERIES L, 1999 | HOLDER | MUVO, 2000 | HOLDER | SERIES B, 2000 | HOLDER | SERIES F, 2000 | HOLDER | SERIES L, 2000 | HOLDER | SERIES A, 2000 | HOLDER | SERIES M, 2000 | HOLDER | SERIES S, 2000 | HOLDER | SERIES C, 2000 | HOLDER | MUVO, 2000 | HOLDER | SERIES V, 2001 | HOLDER | SERIES A, 2001 | HOLDER | SERIES S, 2001 | HOLDER | SERIES F, 2001 | HOLDER | SERIES V, 2001 | HOLDER | SERIES L, 2001 | HOLDER | SERIES M, 2001 | HOLDER | SERIES B, 2001 | HOLDER | SERIES C, 2001 | HOLDER | MUVO, 2002 | HOLDER | SERIES F, 2002 | HOLDER | SERIES B, 2002 | HOLDER | SERIES A, 2002 | HOLDER | MUVO, 2002 | HOLDER | SERIES V, 2002 | HOLDER | SERIES C, 2002 | HOLDER | SERIES S, 2002 | HOLDER | SERIES M, 2002 | HOLDER | SERIES L, 2003 | HOLDER | SERIES M, 2003 | HOLDER | MUVO, 2003 | HOLDER | SERIES C, 2003 | HOLDER | SERIES V, 2003 | HOLDER | SERIES F, 2003 | HOLDER | SERIES L, 2003 | HOLDER | SERIES S, 2003 | HOLDER | SERIES B, 2003 | HOLDER | SERIES A, 2004 | HOLDER | MUVO, 2004 | HOLDER | SERIES A, 2004 | HOLDER | SERIES B, 2004 | HOLDER | SERIES F, 2004 | HOLDER | SERIES L, 2004 | HOLDER | SERIES M, 2004 | HOLDER | SERIES S, 2004 | HOLDER | SERIES C, 2004 | HOLDER | SERIES V, 2005 | HOLDER | SERIES S, 2005 | HOLDER | SERIES C, 2005 | HOLDER | SERIES M, 2005 | HOLDER | SERIES L, 2005 | HOLDER | SERIES A, 2005 | HOLDER | SERIES B, 2005 | HOLDER | MUVO, 2005 | HOLDER | SERIES V, 2005 | HOLDER | SERIES F, 2006 | HOLDER | MUVO, 2006 | HOLDER | SERIES V, 2006 | HOLDER | SERIES C, 2006 | HOLDER | SERIES M, 2006 | HOLDER | SERIES F, 2006 | HOLDER | SERIES B, 2006 | HOLDER | SERIES A, 2006 | HOLDER | SERIES S, 2006 | HOLDER | SERIES L, 2007 | HOLDER | SERIES V, 2007 | HOLDER | SERIES F, 2007 | HOLDER | SERIES C, 2007 | HOLDER | SERIES S, 2007 | HOLDER | SERIES B, 2007 | HOLDER | SERIES L, 2007 | HOLDER | SERIES A, 2007 | HOLDER | SERIES M, 2007 | HOLDER | MUVO, 2008 | HOLDER | SERIES M, 2008 | HOLDER | MUVO, 2008 | HOLDER | SERIES A, 2008 | HOLDER | SERIES F, 2008 | HOLDER | SERIES C, 2008 | HOLDER | SERIES B, 2008 | HOLDER | SERIES V, 2008 | HOLDER | SERIES S, 2008 | HOLDER | SERIES L, 2009 | HOLDER | MUVO, 2009 | HOLDER | SERIES V, 2009 | HOLDER | SERIES B, 2009 | HOLDER | SERIES C, 2009 | HOLDER | SERIES F, 2009 | HOLDER | SERIES S, 2009 | HOLDER | SERIES L, 2009 | HOLDER | SERIES A, 2009 | HOLDER | SERIES M, 2010 | HOLDER | SERIES A, 2010 | HOLDER | SERIES V, 2010 | HOLDER | SERIES L, 2010 | HOLDER | MUVO, 2010 | HOLDER | SERIES F, 2010 | HOLDER | SERIES M, 2010 | HOLDER | SERIES C, 2010 | HOLDER | SERIES B, 2010 | HOLDER | SERIES S, 2011 | HOLDER | SERIES B, 2011 | HOLDER | SERIES F, 2011 | HOLDER | SERIES M, 2011 | HOLDER | SERIES A, 2011 | HOLDER | SERIES S, 2011 | HOLDER | SERIES C, 2011 | HOLDER | SERIES V, 2011 | HOLDER | MUVO, 2011 | HOLDER | SERIES L, 2012 | HOLDER | SERIES A, 2012 | HOLDER | SERIES B, 2012 | HOLDER | SERIES M, 2012 | HOLDER | SERIES V, 2012 | HOLDER | SERIES F, 2012 | HOLDER | SERIES C, 2012 | HOLDER | MUVO, 2012 | HOLDER | SERIES S, 2012 | HOLDER | SERIES L, 2013 | HOLDER | SERIES M, 2013 | HOLDER | SERIES F, 2013 | HOLDER | SERIES C, 2013 | HOLDER | SERIES B, 2013 | HOLDER | SERIES L, 2013 | HOLDER | MUVO, 2013 | HOLDER | SERIES V, 2013 | HOLDER | SERIES S, 2013 | HOLDER | SERIES A, 2014 | HOLDER | SERIES S, 2014 | HOLDER | SERIES B, 2014 | HOLDER | SERIES L, 2014 | HOLDER | MUVO, 2014 | HOLDER | SERIES M, 2014 | HOLDER | SERIES C, 2014 | HOLDER | SERIES A, 2014 | HOLDER | SERIES V, 2014 | HOLDER | SERIES F, 2015 | HOLDER | SERIES L, 2015 | HOLDER | SERIES B, 2015 | HOLDER | SERIES C, 2015 | HOLDER | SERIES M, 2015 | HOLDER | SERIES A, 2015 | HOLDER | SERIES S, 2015 | HOLDER | SERIES V, 2015 | HOLDER | SERIES F, 2015 | HOLDER | MUVO, 2016 | HOLDER | SERIES B, 2016 | HOLDER | SERIES C, 2016 | HOLDER | SERIES F, 2016 | HOLDER | SERIES V, 2016 | HOLDER | SERIES M, 2016 | HOLDER | SERIES L, 2016 | HOLDER | MUVO, 2016 | HOLDER | SERIES A, 2016 | HOLDER | SERIES S, 2017 | HOLDER | SERIES L, 2017 | HOLDER | SERIES F, 2017 | HOLDER | MUVO, 2017 | HOLDER | SERIES V, 2017 | HOLDER | SERIES S, 2017 | HOLDER | SERIES A, 2017 | HOLDER | SERIES M, 2017 | HOLDER | SERIES C, 2017 | HOLDER | SERIES B, 2018 | HOLDER | SERIES F, 2018 | HOLDER | SERIES L, 2018 | HOLDER | SERIES A, 2018 | HOLDER | SERIES S, 2018 | HOLDER | SERIES V, 2018 | HOLDER | SERIES C, 2018 | HOLDER | SERIES B, 2018 | HOLDER | MUVO, 2018 | HOLDER | SERIES M, 2019 | HOLDER | SERIES S, 2019 | HOLDER | SERIES M, 2019 | HOLDER | SERIES L, 2019 | HOLDER | SERIES F, 2019 | HOLDER | SERIES C, 2019 | HOLDER | SERIES V, 2019 | HOLDER | MUVO, 2019 | HOLDER | SERIES B, 2019 | HOLDER | SERIES A, 2020 | HOLDER | SERIES V, 2020 | HOLDER | SERIES B, 2020 | HOLDER | SERIES L, 2020 | HOLDER | SERIES C, 2020 | HOLDER | SERIES M, 2020 | HOLDER | MUVO, 2020 | HOLDER | SERIES A, 2020 | HOLDER | SERIES S, 2020 | HOLDER | SERIES F
Problème
Ce rappel concerne certains véhicules polyvalents utilisés pour le déneigement, le nettoyage des rues et d'autres opérations d'entretien. Dans certaines conditions, le véhicule pourrait accélérer brusquement. En outre, selon les réglages du véhicule, le démarrage du moteur pourrait entraîner le démarrage automatique de la prise de force. Note : Ce rappel n'est pas effectué en vertu des exigences de la Loi sur la sécurité des véhicules automobiles.
Risques pour la sécurité
Un véhicule qui accélère soudainement pourrait créer un risque de collision. Un dispositif de prise de force qui démarre automatiquement pourrait créer un risque de blessure pour le conducteur ou les personnes se trouvant à proximité.
Mesures correctives
Le détenteur doit fournir aux propriétaires et aux concessionnaires un avis de sécurité qui comporte les mesures de sécurité que tous les utilisateurs doivent suivre. Les utilisateurs doivent également se référer au manuel d'utilisation pour obtenir des informations sur la bonne manière d'utiliser le véhicule. Les mesures correctives pour ce rappel sont en cours d'élaboration.
Contexte
Vous pouvez trouver le rappel d’origine dans la Banque de données des rappels de sécurité automobile de Transports Canada.
Renseignements supplémentaires
Détails