Search
Type
Audience
Category
Issue
Last updated
Recall class
Please note: using the search filters may not provide accurate search results for records prior to November 2021. When searching for older records, please ensure that you use the include archive checkbox.
Displaying 1 - 15 of 3696 items.
Affected lots may contain the presence of Cronobacter contamination.
RecallHealth product recall | 2023-02-02
Product was identified as potentially non-sterile as it received an underdose of gamma irradiation during the sterilization process. As the sterilization dose was not achieved, the sterility assurance level cannot be guaranteed.
Recall start date:…
RecallHealth product recall | 2023-02-01
Non-licensed inventory was sent to Canada via web shop orders starting in February of 2022.
Recall start date: December 12, 2022
RecallHealth product recall | 2023-01-31
Affected lots may contain the presence of foreign matter.
RecallHealth product recall | 2023-01-31
During internal studies with the Elecsys® Troponin T hs (high sensitive) and Elecsys® Troponin T hs Stat assays, it was confirmed that for certain k2/k3 EDTA primary tubes, TnT hs results are elevated compared to serum samples when measured…
RecallHealth product recall | 2023-01-31
Beckman Coulter has determined that the Access 2 wash arm lead screw nut band is susceptible to breakage. An Access 2 Immunoassay system wash arm may not move as intended if the nut band is broken. A broken nut band may increase the risk of erroneous…
RecallHealth product recall | 2023-01-31
BVI has received a complaint from a customer that catalog # 376630 of the Beaver Edgehead Stiletto/Mvr knife 0.90 mm Straight (20g), a component of the Readpak kit (cat:584896, lots:6054175,6053035), was shipped with an open head. BVI is recalling the…
RecallHealth product recall | 2023-01-26
There is a potential malfunction with the side-port of the Triever 24. The side-port may potentially leak or dislodge during device preparation or during actual use. The side-port of the triever24 catheter is used in combination with a 60cc large bore…
RecallHealth product recall | 2023-01-26
Summit Medical received a customer complaint that Nasal Septal Button, 5cm, SP-78105 parts received from lot# 219349 were in unsealed pouched. The product was sterilized, but if this sterile barrier is not sealed, there is a possibility of product…
RecallHealth product recall | 2023-01-26
Cardinal Health has initiated a medical device correction for specific production lots of the Cardinal Health™ Jackson-Pratt™ channel drains. The recall is being issued due to various performance issues including lack of radiopacity in wound drains, dull…
RecallHealth product recall | 2023-01-25
The manufacturer of Statis SL handpieces has informed SciCan that the product may not function as expected if not properly maintained. When using the Statis handpieces, the lack of care or age-related wear and tear could result in the loosening parts…
RecallHealth product recall | 2023-01-25
Manufacturer initiated recall notifying users of variability of only the level 1 troponin I values included in the Mas CardioImmune XL controls (confirmed after 8 complaints). The level 1 control is included in lots of control kits CAI-XL 1, CAI-XL4…
RecallHealth product recall | 2023-01-24
In case the magnets of the Novastar TS and Novastar Plus are positioned near medical devices (implanted as well as not-implanted) and metallic implants the magnetic field might impact the implants or devices and cause serious injury.
Recall start date…
RecallHealth product recall | 2023-01-24
The catheter repair adhesive used to attach the repair segment to the original catheter is hardened/coagulated (unusable).
Recall start date: January 4, 2023
RecallHealth product recall | 2023-01-19
Defective hard drives were identified in the graphical user interface tablet of some devices. The defective component leads to tablet screen freeze and reboot occurrences, eventually rendering the transcranial doppler (TCD) ultrasound system inoperable…
RecallHealth product recall | 2023-01-18