Transport Canada Recall - 2021723 -
Summary
Please see corrective actions section below
Affected products
1997 | TOYOTA | CAMRY, 1998 | TOYOTA | COROLLA, 1999 | TOYOTA | COROLLA, 1999 | TOYOTA | TERCEL, 2000 | TOYOTA | ECHO, 2000 | TOYOTA | CELICA, 2000 | TOYOTA | COROLLA, 2001 | TOYOTA | ECHO, 2001 | TOYOTA | SIENNA, 2001 | TOYOTA | COROLLA, 2001 | TOYOTA | RAV4, 2002 | TOYOTA | ECHO, 2002 | TOYOTA | RAV4, 2002 | TOYOTA | COROLLA, 2002 | TOYOTA | CAMRY, 2003 | TOYOTA | COROLLA, 2003 | TOYOTA | CAMRY, 2003 | TOYOTA | 4RUNNER, 2003 | TOYOTA | RAV4, 2003 | TOYOTA | CELICA, 2003 | TOYOTA | ECHO, 2003 | TOYOTA | MATRIX, 2004 | TOYOTA | MATRIX, 2004 | TOYOTA | YARIS, 2004 | TOYOTA | ECHO, 2004 | TOYOTA | PRIUS, 2004 | TOYOTA | COROLLA, 2004 | TOYOTA | CELICA, 2004 | TOYOTA | RAV4, 2004 | TOYOTA | 4RUNNER, 2004 | TOYOTA | CAMRY, 2005 | TOYOTA | MATRIX, 2005 | TOYOTA | YARIS, 2005 | TOYOTA | TACOMA, 2005 | TOYOTA | SOLARA, 2005 | TOYOTA | AVALON, 2005 | TOYOTA | PRIUS, 2005 | TOYOTA | ECHO, 2005 | TOYOTA | SIENNA, 2005 | TOYOTA | COROLLA, 2005 | TOYOTA | 4RUNNER, 2005 | TOYOTA | RAV4, 2005 | TOYOTA | CAMRY, 2006 | LEXUS | IS 250, 2006 | TOYOTA | MATRIX, 2006 | LEXUS | IS 350, 2006 | TOYOTA | YARIS, 2006 | TOYOTA | RAV4, 2006 | TOYOTA | PRIUS, 2006 | TOYOTA | SIENNA, 2006 | TOYOTA | HIGHLANDER HYBRID, 2006 | TOYOTA | COROLLA, 2006 | TOYOTA | TACOMA, 2006 | TOYOTA | 4RUNNER, 2006 | TOYOTA | AVALON, 2006 | LEXUS | GS 300, 2006 | TOYOTA | CAMRY, 2007 | TOYOTA | CAMRY, 2007 | TOYOTA | COROLLA, 2007 | TOYOTA | TACOMA, 2007 | TOYOTA | 4RUNNER, 2007 | TOYOTA | AVALON, 2007 | TOYOTA | TUNDRA, 2007 | TOYOTA | RAV4, 2007 | TOYOTA | SOLARA, 2007 | TOYOTA | PRIUS, 2007 | TOYOTA | SIENNA, 2007 | TOYOTA | FJ CRUISER, 2007 | LEXUS | IS 250, 2007 | TOYOTA | MATRIX, 2007 | LEXUS | LS 460, 2007 | TOYOTA | YARIS, 2007 | LEXUS | GS 350, 2007 | LEXUS | ES 350, 2007 | LEXUS | GS 450H, 2007 | LEXUS | RX 350, 2007 | TOYOTA | CAMRY HYBRID, 2008 | TOYOTA | YARIS, 2008 | LEXUS | GS 350, 2008 | LEXUS | ES 350, 2008 | LEXUS | IS F, 2008 | LEXUS | LS 600H, 2008 | LEXUS | GS 460, 2008 | LEXUS | RX 350, 2008 | TOYOTA | CAMRY HYBRID, 2008 | LEXUS | LX 570, 2008 | TOYOTA | LAND CRUISER, 2008 | TOYOTA | CAMRY, 2008 | TOYOTA | COROLLA, 2008 | TOYOTA | TACOMA, 2008 | TOYOTA | 4RUNNER, 2008 | TOYOTA | TUNDRA, 2008 | TOYOTA | RAV4, 2008 | TOYOTA | PRIUS, 2008 | TOYOTA | HIGHLANDER, 2008 | TOYOTA | SEQUOIA, 2008 | LEXUS | IS 250, 2008 | TOYOTA | SIENNA, 2008 | TOYOTA | FJ CRUISER, 2008 | LEXUS | LS 460, 2008 | LEXUS | RX 400H, 2008 | TOYOTA | MATRIX, 2009 | TOYOTA | VENZA, 2009 | LEXUS | LS 460, 2009 | SCION | XB, 2009 | LEXUS | RX 350, 2009 | TOYOTA | CAMRY HYBRID, 2009 | TOYOTA | CAMRY, 2009 | TOYOTA | COROLLA, 2009 | TOYOTA | TACOMA, 2009 | TOYOTA | 4RUNNER, 2009 | TOYOTA | TUNDRA, 2009 | TOYOTA | RAV4, 2009 | TOYOTA | PRIUS, 2009 | TOYOTA | HIGHLANDER, 2009 | LEXUS | IS 250, 2009 | TOYOTA | SIENNA, 2009 | TOYOTA | MATRIX, 2009 | TOYOTA | YARIS, 2009 | LEXUS | GS 350, 2009 | LEXUS | ES 350, 2009 | LEXUS | IS F, 2010 | LEXUS | RX 350, 2010 | TOYOTA | VENZA, 2010 | LEXUS | ES 350, 2010 | LEXUS | RX 450H, 2010 | LEXUS | HS 250H, 2010 | LEXUS | GX 460, 2010 | LEXUS | IS 250C, 2010 | TOYOTA | COROLLA, 2010 | TOYOTA | CAMRY, 2010 | TOYOTA | TACOMA, 2010 | TOYOTA | 4RUNNER, 2010 | TOYOTA | TUNDRA, 2010 | TOYOTA | RAV4, 2010 | TOYOTA | PRIUS, 2010 | TOYOTA | AVALON, 2010 | TOYOTA | SEQUOIA, 2010 | TOYOTA | HIGHLANDER, 2010 | TOYOTA | FJ CRUISER, 2010 | TOYOTA | SIENNA, 2010 | TOYOTA | MATRIX, 2010 | LEXUS | LS 460, 2010 | TOYOTA | YARIS, 2010 | LEXUS | IS F, 2011 | LEXUS | GS 350, 2011 | LEXUS | IS F, 2011 | LEXUS | RX 350, 2011 | TOYOTA | VENZA, 2011 | TOYOTA | YARIS, 2011 | LEXUS | ES 350, 2011 | LEXUS | LX 570, 2011 | LEXUS | RX 450H, 2011 | LEXUS | GX 460, 2011 | SCION | XB, 2011 | SCION | TC, 2011 | SCION | XD, 2011 | TOYOTA | CAMRY HYBRID, 2011 | TOYOTA | COROLLA, 2011 | TOYOTA | CAMRY, 2011 | TOYOTA | TACOMA, 2011 | TOYOTA | 4RUNNER, 2011 | TOYOTA | AVALON, 2011 | TOYOTA | TUNDRA, 2011 | TOYOTA | RAV4, 2011 | TOYOTA | PRIUS, 2011 | TOYOTA | SEQUOIA, 2011 | TOYOTA | HIGHLANDER, 2011 | LEXUS | IS 250, 2011 | TOYOTA | SIENNA, 2011 | TOYOTA | MATRIX, 2011 | LEXUS | IS 350, 2011 | LEXUS | LS 460, 2012 | LEXUS | LS 460, 2012 | LEXUS | IS F, 2012 | TOYOTA | MATRIX, 2012 | LEXUS | RX 350, 2012 | TOYOTA | VENZA, 2012 | TOYOTA | YARIS, 2012 | LEXUS | ES 350, 2012 | LEXUS | GX 460, 2012 | SCION | XB, 2012 | SCION | TC, 2012 | TOYOTA | PRIUS C, 2012 | LEXUS | CT 200H, 2012 | SCION | XD, 2012 | TOYOTA | PRIUS V, 2012 | TOYOTA | CAMRY HYBRID, 2012 | TOYOTA | COROLLA, 2012 | TOYOTA | CAMRY, 2012 | TOYOTA | TACOMA, 2012 | TOYOTA | 4RUNNER, 2012 | TOYOTA | AVALON, 2012 | TOYOTA | PRIUS, 2012 | TOYOTA | TUNDRA, 2012 | TOYOTA | RAV4, 2012 | TOYOTA | SEQUOIA, 2012 | TOYOTA | HIGHLANDER, 2012 | TOYOTA | HIGHLANDER HYBRID, 2012 | LEXUS | IS 250, 2012 | TOYOTA | SIENNA, 2012 | TOYOTA | FJ CRUISER, 2012 | LEXUS | IS 350, 2013 | SCION | TC, 2013 | TOYOTA | PRIUS C, 2013 | LEXUS | CT 200H, 2013 | SCION | XD, 2013 | TOYOTA | PRIUS V, 2013 | LEXUS | RX 450H, 2013 | TOYOTA | CAMRY HYBRID, 2013 | LEXUS | IS 350C, 2013 | LEXUS | LX 570, 2013 | LEXUS | ES 300H, 2013 | LEXUS | LS 600H, 2013 | LEXUS | RX 350, 2013 | TOYOTA | VENZA, 2013 | LEXUS | GX 460, 2013 | TOYOTA | YARIS, 2013 | LEXUS | ES 350, 2013 | LEXUS | LS 460, 2013 | LEXUS | IS F, 2013 | TOYOTA | MATRIX, 2013 | LEXUS | GS 350, 2013 | TOYOTA | HIGHLANDER HYBRID, 2013 | TOYOTA | SEQUOIA, 2013 | LEXUS | IS 250, 2013 | TOYOTA | SIENNA, 2013 | TOYOTA | FJ CRUISER, 2013 | TOYOTA | HIGHLANDER, 2013 | TOYOTA | TUNDRA, 2013 | TOYOTA | AVALON, 2013 | TOYOTA | PRIUS, 2013 | TOYOTA | RAV4, 2013 | TOYOTA | TACOMA, 2013 | TOYOTA | 4RUNNER, 2013 | TOYOTA | CAMRY, 2013 | TOYOTA | COROLLA, 2014 | SCION | TC, 2014 | LEXUS | GX 460, 2014 | LEXUS | ES 350, 2014 | LEXUS | LS 460, 2014 | LEXUS | IS F, 2014 | TOYOTA | MATRIX, 2014 | LEXUS | RX 350, 2014 | TOYOTA | VENZA, 2014 | LEXUS | IS 350C, 2014 | LEXUS | LX 570, 2014 | SCION | XB, 2014 | LEXUS | LS 600H, 2014 | SCION | XD, 2014 | LEXUS | ES 300H, 2014 | LEXUS | RX 450H, 2014 | TOYOTA | CAMRY HYBRID, 2014 | TOYOTA | PRIUS C, 2014 | TOYOTA | COROLLA, 2014 | TOYOTA | CAMRY, 2014 | TOYOTA | AVALON, 2014 | TOYOTA | RAV4, 2014 | TOYOTA | TACOMA, 2014 | TOYOTA | 4RUNNER, 2014 | TOYOTA | TUNDRA, 2014 | TOYOTA | FJ CRUISER, 2014 | TOYOTA | HIGHLANDER HYBRID, 2014 | TOYOTA | SEQUOIA, 2014 | LEXUS | IS 250, 2014 | TOYOTA | SIENNA, 2014 | TOYOTA | HIGHLANDER, 2014 | LEXUS | GS 350, 2014 | LEXUS | IS 350, 2014 | TOYOTA | YARIS, 2015 | LEXUS | GX 460, 2015 | LEXUS | LS 460, 2015 | LEXUS | RX 350, 2015 | TOYOTA | VENZA, 2015 | LEXUS | ES 350, 2015 | LEXUS | LX 570, 2015 | SCION | XB, 2015 | TOYOTA | CAMRY HYBRID, 2015 | LEXUS | RC F, 2015 | TOYOTA | PRIUS V, 2015 | LEXUS | NX 200T, 2015 | LEXUS | NX 300H, 2015 | TOYOTA | PRIUS C, 2015 | LEXUS | CT 200H, 2015 | LEXUS | RC 350, 2015 | SCION | TC, 2015 | TOYOTA | COROLLA, 2015 | TOYOTA | 4RUNNER, 2015 | TOYOTA | RAV4, 2015 | TOYOTA | CAMRY, 2015 | TOYOTA | AVALON, 2015 | TOYOTA | PRIUS, 2015 | TOYOTA | TACOMA, 2015 | TOYOTA | TUNDRA, 2015 | TOYOTA | SEQUOIA, 2015 | LEXUS | IS 250, 2015 | TOYOTA | SIENNA, 2015 | TOYOTA | HIGHLANDER, 2015 | LEXUS | GS 350, 2015 | TOYOTA | HIGHLANDER HYBRID, 2015 | LEXUS | IS 350, 2015 | TOYOTA | YARIS, 2016 | SCION | TC, 2016 | TOYOTA | PRIUS C, 2016 | LEXUS | LS 460, 2016 | TOYOTA | CAMRY HYBRID, 2016 | LEXUS | RX 350, 2016 | TOYOTA | VENZA, 2016 | LEXUS | ES 350, 2016 | LEXUS | NX 300H, 2016 | LEXUS | LX 570, 2016 | LEXUS | NX 200T, 2016 | LEXUS | RC F, 2016 | LEXUS | ES 300H, 2016 | TOYOTA | RAV4 HYBRID, 2016 | LEXUS | CT 200H, 2016 | LEXUS | IS 200T, 2016 | LEXUS | GS F, 2016 | LEXUS | RC 350, 2016 | SCION | IM, 2016 | TOYOTA | COROLLA, 2016 | TOYOTA | 4RUNNER, 2016 | TOYOTA | RAV4, 2016 | TOYOTA | CAMRY, 2016 | TOYOTA | AVALON, 2016 | TOYOTA | TACOMA, 2016 | TOYOTA | HIGHLANDER, 2016 | TOYOTA | PRIUS, 2016 | TOYOTA | TUNDRA, 2016 | TOYOTA | SEQUOIA, 2016 | TOYOTA | SIENNA, 2016 | TOYOTA | HIGHLANDER HYBRID, 2016 | LEXUS | IS 350, 2016 | LEXUS | GS 350, 2016 | TOYOTA | YARIS, 2016 | LEXUS | GX 460, 2017 | TOYOTA | COROLLA, 2017 | TOYOTA | 4RUNNER, 2017 | TOYOTA | RAV4, 2017 | TOYOTA | CAMRY, 2017 | TOYOTA | AVALON, 2017 | TOYOTA | TACOMA, 2017 | TOYOTA | HIGHLANDER, 2017 | TOYOTA | PRIUS, 2017 | TOYOTA | TUNDRA, 2017 | TOYOTA | SEQUOIA, 2017 | TOYOTA | SIENNA, 2017 | TOYOTA | HIGHLANDER HYBRID, 2017 | LEXUS | IS 350, 2017 | LEXUS | GS 350, 2017 | TOYOTA | YARIS, 2017 | LEXUS | LS 460, 2017 | TOYOTA | CAMRY HYBRID, 2017 | LEXUS | RX 350, 2017 | LEXUS | GX 460, 2017 | LEXUS | ES 350, 2017 | LEXUS | NX 300H, 2017 | LEXUS | LX 570, 2017 | LEXUS | NX 200T, 2017 | LEXUS | RC 350, 2017 | TOYOTA | PRIUS V, 2017 | TOYOTA | COROLLA HATCHBACK, 2017 | LEXUS | ES 300H, 2017 | LEXUS | CT 200H, 2017 | LEXUS | IS 200T, 2017 | TOYOTA | RAV4 HYBRID, 2017 | LEXUS | GS F, 2017 | LEXUS | RC F, 2017 | TOYOTA | PRIUS C, 2017 | TOYOTA | PRIUS PRIME, 2018 | TOYOTA | CAMRY HYBRID, 2018 | LEXUS | RX 350, 2018 | LEXUS | GS 450H, 2018 | TOYOTA | COROLLA HATCHBACK, 2018 | LEXUS | ES 300H, 2018 | LEXUS | IS 200T, 2018 | LEXUS | IS 300, 2018 | TOYOTA | RAV4 HYBRID, 2018 | TOYOTA | C-HR, 2018 | TOYOTA | TUNDRA, 2018 | TOYOTA | HIGHLANDER, 2018 | TOYOTA | SEQUOIA, 2018 | TOYOTA | SIENNA, 2018 | LEXUS | GS 350, 2018 | TOYOTA | HIGHLANDER HYBRID, 2018 | LEXUS | ES 350, 2018 | TOYOTA | YARIS, 2018 | LEXUS | GX 460, 2018 | TOYOTA | COROLLA, 2018 | TOYOTA | 4RUNNER, 2018 | TOYOTA | CAMRY, 2018 | TOYOTA | TACOMA, 2018 | TOYOTA | AVALON, 2018 | TOYOTA | RAV4, 2018 | TOYOTA | PRIUS, 2019 | TOYOTA | COROLLA HATCHBACK, 2019 | TOYOTA | C-HR, 2019 | TOYOTA | TUNDRA, 2019 | TOYOTA | SEQUOIA, 2019 | LEXUS | GS 350, 2019 | TOYOTA | HIGHLANDER HYBRID, 2019 | TOYOTA | YARIS, 2019 | LEXUS | GX 460, 2019 | TOYOTA | 4RUNNER, 2019 | TOYOTA | TACOMA, 2019 | TOYOTA | HIGHLANDER, 2019 | TOYOTA | RAV4, 2019 | TOYOTA | SIENNA, 2020 | LEXUS | GX 460, 2020 | TOYOTA | COROLLA HATCHBACK, 2020 | TOYOTA | C-HR, 2020 | TOYOTA | TUNDRA, 2020 | TOYOTA | COROLLA, 2020 | TOYOTA | SIENNA, 2021 | TOYOTA | C-HR, 2021 | TOYOTA | TUNDRA, 2021 | TOYOTA | COROLLA, 2022 | TOYOTA | COROLLA CROSS
Issue
This recall is for certain block heater kits installed on certain vehicles or sold as accessories at Toyota or Lexus dealerships. On certain vehicles, the engine block heater cable may not have enough heat protection and could be damaged by high temperatures. If this happens, the cable could short circuit while plugged in, and cause the wiring to overheat or melt. Note: This recall only affects the following block heater/cord part numbers: C014003034 PK5A408J09 PU14000904 C014003151 PK5A408J13 PU14000905 C014000885 PK5A489J11 PU14000907 C014000888 PK5A489J22 PU14000909 C014000907 PK5A410H00 PU14000911 C014100904 PU14000900 PU14000913 C014100907 PU14000901 PU14003571 C014100911 PU14000902 PK5A489J14 PK5A408J05 PU14000903
Safety risk
Engine block heater wiring that overheats or melts could create the risk of a fire.
Corrective actions
Toyota recommends that you should stop using the engine block heater immediately. Toyota will notify owners by mail and instruct you to take your vehicle to a dealer to disable the engine block heater. For some vehicles, the corrective actions for this recall are under development. For others, a new engine block heater cannot be installed, and the owner will receive a refund of the purchase price of the engine block heater.
Background
Visit Transport Canada’s Motor Vehicle Safety Recalls Database for the original recall.
Additional information
Details