Transport Canada Recall - 2020470 -
Brand(s)
Summary
Please see corrective actions section below
Affected products
2020 | KEYSTONE | HIDEOUT
Issue
One travel trailer was built with the wrong tires and axles with the wrong load rating. The trailer was built with axles rated for 1587 kg (3500 lb.) and ST205/75R14D tires. The trailer should have axles rated for 1995 kg (4400 lb.) and ST225/75R15D tires. As a result, the axles and tires could be overloaded. This could result in an axle or tire failure.
Safety risk
An axle or tire failure could cause a loss of control and increase the risk of a crash.
Corrective actions
Keystone will notify the owner by mail and instruct them to take their trailer to a dealer to replace the axles, tires and rims with parts rated for 1995 kg (4400 lb.)
Background
Visit Transport Canada’s Motor Vehicle Safety Recalls Database for the original recall.
Additional information
Details
Get notified
Receive emails about new and updated recall and safety alerts.