Transport Canada Recall - 2018706 -
Brand(s)
Summary
Please see corrective actions section below
Affected products
2008 | LEXUS | LX 570, 2009 | LEXUS | LX 570, 2010 | LEXUS | LX 570, 2011 | LEXUS | LX 570, 2012 | LEXUS | LX 570, 2013 | LEXUS | LX 570, 2014 | LEXUS | LX 570, 2015 | LEXUS | LX 570, 2016 | LEXUS | LX 570, 2017 | LEXUS | LX 570, 2018 | LEXUS | LX 570, 2019 | LEXUS | LX 570
Issue
On certain vehicles, the seat belt tension sensor wiring of the front passenger occupant classification system could fatigue and break over time. This could result in the front passenger airbag, knee airbag, and passenger seat-mounted side airbag to become deactivated, which in the event of crash, could increase the risk of injury to the occupant. Correction: Dealers will modify or replace the front passenger seat belt assembly as necessary. Note: If the tension sensor wiring were to break it could cause the airbag warning light and the passenger airbag "OFF" indicator to illuminate.
Additional information
Background
Visit Transport Canada’s Motor Vehicle Safety Recalls Database for the original recall.
Details
Get notified
Receive emails about new and updated recall and safety alerts.