Vehicle recall

Transport Canada Recall - 2017064 - VAN HOOL

Brand(s)
Last updated

Summary

Product
Bus recalled by VAN HOOL
Issue
Vehicle - Steering
What to do

Please see corrective actions section below

Affected products

2010 | VAN HOOL | T2145, 2011 | VAN HOOL | C2045, 2011 | VAN HOOL | T2145, 2012 | VAN HOOL | C2045, 2012 | VAN HOOL | T2145, 2013 | VAN HOOL | TD925, 2014 | VAN HOOL | T2145, 2014 | VAN HOOL | TD925

Issue

On certain buses, the grease used in the first generation Pailton bevel gear box is not suited for low temperatures (-20 degree Celsius). Additionally, water could penetrate the bevel box through the seal, contaminating the grease and causing corrosion in the bearings. A combination of corrosion, contaminated grease and low temperatures would increase steering effort and, over time, could result in the sudden loss of operational steering which could increase the risk of a crash causing injury and/or damage to property. Correction: Dealers will replace the first generation Pailton bevel box with a ZF bevel box.

Additional information

Background

Visit Transport Canada’s Motor Vehicle Safety Recalls Database for the original recall.

Details
Original published date:
Alert / recall type
Vehicle recall
Category
Vehicles - Bus
Companies
Published by
Transport Canada
Audience
General public
Identification number
RA-68393
Transport Canada ID
2017064

Get notified

Receive emails about new and updated recall and safety alerts.