Transport Canada Recall - 2016586 - TOYOTA
Brand(s)
Summary
Please see corrective actions section below
Affected products
2011 | TOYOTA | SIENNA, 2012 | TOYOTA | SIENNA, 2013 | TOYOTA | SIENNA, 2014 | TOYOTA | SIENNA, 2015 | TOYOTA | SIENNA, 2016 | TOYOTA | SIENNA
Issue
On certain vehicles equipped with power sliding doors, under certain conditions which impede the opening of the door (such as if the door becomes frozen with ice), the sliding door motor could stall when the door is operated. If the motor stalls, high current in the door motor circuit could be generated, operating the circuit protection for the door motor. If this occurs with the sliding door latch mechanism in an unlatched position, the door could open while driving, increasing the risk of injury to a vehicle occupant. Correction: Dealers will replace the existing junction block and the rear sliding door wire harnesses with newly designed ones. The dealer will also install two sub wire harnesses to connect the junction block to the two rear door wire harnesses.