Transport Canada Recall - 2016314 - YAMAHA
Brand(s)
Summary
Please see corrective actions section below
Affected products
2015 | YAMAHA | YZF-R3, 2016 | YAMAHA | YZF-R3
Issue
On certain motorcycles, the clutch pressure plate bearing may break if operated frequently due to an insufficient load rating of the bearing. This could cause the clutch to fail, and the transmission to not shift properly. In addition, oil pressure may not be properly regulated due to an improper oil relief valve design in the oil pump, which can excessively stress the oil pump drive gear. This could result in the gear breaking, which could result in engine seizure from lack of oil supply. Either of these conditions could increase the risk of a crash causing injury and/or property damage. Correction: Dealers will replace the clutch pressure plate assembly and oil pump assembly with parts of a different design.
Additional information
Background
Visit Transport Canada’s Motor Vehicle Safety Recalls Database for the original recall.