Transport Canada Recall - 2014236 - MOTOR COACH INDUSTRIES
Brand(s)
Summary
Please see corrective actions section below
Affected products
2009 | MCI | D4000, 2009 | MCI | D4500, 2009 | MCI | D4505, 2010 | MCI | D4000, 2010 | MCI | D4500, 2010 | MCI | D4505, 2011 | MCI | D4000, 2011 | MCI | D4500, 2011 | MCI | D4505
Issue
Certain coaches previously repaired as part of recall 2012173 may require additional modifications. The power draw from the LED interior lights may exceed the design limits of the fuse block terminal and power splice connector installed as part of the previous recall. As a result, these components could overheat, potentially resulting in a vehicle fire causing property damage and/or personal injury. Correction: MCI authorized facilities will install a revised fuse holder for the LED interior lights.
Additional information
Background
Visit Transport Canada’s Motor Vehicle Safety Recalls Database for the original recall.
Details
Get notified
Receive emails about new and updated recall and safety alerts.