Transport Canada Recall - 2012256 - ELGIN SWEEPER
Brand(s)
Summary
Please see corrective actions section below
Affected products
2008 | ELGIN SWEEPER | CROSSWIND, 2008 | ELGIN SWEEPER | EAGLE, 2008 | ELGIN SWEEPER | MEGAWIND, 2008 | ELGIN SWEEPER | ROAD WIZARD, 2008 | ELGIN SWEEPER | WHIRLWIND, 2009 | ELGIN SWEEPER | CROSSWIND, 2009 | ELGIN SWEEPER | EAGLE, 2009 | ELGIN SWEEPER | MEGAWIND, 2009 | ELGIN SWEEPER | ROAD WIZARD, 2009 | ELGIN SWEEPER | WHIRLWIND, 2010 | ELGIN SWEEPER | CROSSWIND, 2010 | ELGIN SWEEPER | EAGLE, 2010 | ELGIN SWEEPER | MEGAWIND, 2010 | ELGIN SWEEPER | ROAD WIZARD, 2010 | ELGIN SWEEPER | WHIRLWIND
Issue
On some street sweepers built on UD Truck chassis, the air brake system may not comply with Canada Motor Vehicle Safety Standard 121- Air Brake Systems. During the conversion into a street sweeper, the primary and secondary circuits may have been tied together and may no longer be isolated. This would cause a loss of both the front and rear service brakes in the event of an air leak in either service brake circuit, which could result in a reduction of braking performance, increased stopping distances, loss of system pressure and/or emergency brake application. Correction: Elgin authorized repair facilities will inspect the air lines and re-route as necessary.
Additional information
Background
Visit Transport Canada’s Motor Vehicle Safety Recalls Database for the original recall.
Details
Get notified
Receive emails about new and updated recall and safety alerts.