Transport Canada Recall - 2011283 - FLEETWOOD
Brand(s)
Summary
Please see corrective actions section below
Affected products
2010 | FLEETWOOD | DISCOVERY, 2010 | FLEETWOOD | REVOLUTION LE, 2011 | FLEETWOOD | AMERICAN EAGLE, 2011 | FLEETWOOD | BOUNDER, 2011 | FLEETWOOD | BOUNDER CLASSIC, 2011 | FLEETWOOD | DISCOVERY, 2011 | FLEETWOOD | EXPEDITION, 2011 | FLEETWOOD | REVOLUTION LE, 2011 | FLEETWOOD | SOUTHWIND
Issue
On certain motorhomes, a one inch plug-in circuit breaker (single pole 15, 20 or 30 amps) may have a non-conforming "spring clip" plug-in assembly that breaks or fails to provide sufficient force to maintain a proper electrical connection. Over time, this could lead to excessive temperature, arcing or thermal damage at the connection point. This could lead to a fire causing property damage and/or personal injury. Correction: Dealers will replace affected circuit breakers.
Additional information
Background
Visit Transport Canada’s Motor Vehicle Safety Recalls Database for the original recall.