Transport Canada Recall - 2010429 - KEYSTONE
Brand(s)
Summary
Please see corrective actions section below
Affected products
2011 | KEYSTONE | COUGAR 26SAB, 2011 | KEYSTONE | FUZION, 2011 | KEYSTONE | SPRINTER
Issue
On certain travel trailers, one inch plug-in circuit breakers (single & double pole 15 - 50 amps) may have a non-conforming "spring clip" plug-in assembly that breaks or fails to provide sufficient force to maintain a proper electrical connection in the panel board. Over time, this condition could lead to excessive temperature, arcing, or thermal damage at the connection point, and potential damage to the electrical insulation of the panel board. This could lead to a fire, property damage, or personal injury. Correction: Dealers will inspect and remove all affected breakers from the distribution panel, and replace them with new breakers.
Additional information
Background
Visit Transport Canada’s Motor Vehicle Safety Recalls Database for the original recall.