Transport Canada Recall - 2010372 - PACCAR
Brand(s)
Summary
Please see corrective actions section below
Affected products
2009 | KENWORTH | T660, 2009 | KENWORTH | T700, 2009 | KENWORTH | T800, 2009 | KENWORTH | W900, 2010 | KENWORTH | T660, 2010 | KENWORTH | T700, 2010 | KENWORTH | T800, 2010 | KENWORTH | W900, 2011 | KENWORTH | T660, 2011 | KENWORTH | T700, 2011 | KENWORTH | T800, 2011 | KENWORTH | W900
Issue
On certain vehicles equipped with the AG400L suspension and air disc brakes, a caliper could be installed on the wrong side of the drive axle. This could cause interference with the suspension bracket and U-bolts as the outermost brake pads wear and the floating caliper moves inboard. As this interference gets larger, it prohibits the movement of the floating caliper, subsequently reducing the outer pad's pressure on the disc which can eventually lead to reduced braking performance and increasing the risk of a crash. Correction: Dealers will inspect and, if necessary, replace one drive axle brake caliper.
Additional information
Background
Visit Transport Canada’s Motor Vehicle Safety Recalls Database for the original recall.
Details