Transport Canada Recall - 2010222 - BLUE BIRD
Brand(s)
Summary
Please see corrective actions section below
Affected products
2010 | BLUE BIRD | ALL AMERICAN SCHOOL BUS
Issue
On certain D3 All American school buses, the weld around the steering shaft tube, which joins the splined tube to the non-splined intermediate tube, may be mislocated. An improperly located weld bead may allow the splined tube and non-splined tube to rotate relative one another during a low speed, high torque turn, resulting in a possible separation of the tubes. This could cause a loss of steering control which could result in a crash causing property damage and/or personal injury. Correction: Dealers will inspect and, if necessary, replace the steering shaft.
Additional information
Background
Visit Transport Canada’s Motor Vehicle Safety Recalls Database for the original recall.