Health product recall

Siemens Dimension Assays (2016-03-22)

Starting date:
March 22, 2016
Posting date:
April 22, 2016
Type of communication:
Medical Device Recall
Subcategory:
Medical Device
Hazard classification:
Type III
Source of recall:
Health Canada
Issue:
Medical Devices
Audience:
General Public, Healthcare Professionals, Hospitals
Identification number:
RA-58054

Affected Products

A. DIMENSION VISTA SYSTEM - HIGH DENSITY LIPOPROTEIN CHOLESTEROL ASSAY

B. DIMENSION VISTA SYSTEM - URIC ACID ASSAY

C. DIMENSION VISTA SYSTEM - TRIGLYCERIDES ASSAY

D. DIMENSION CLINICAL CHEMISTRY SYS - ENZYMATIC CREATININE ECRE FLEX REAG CART

E. DIMENSION CLINICAL CHEMISTRY SYSTEM - TRIG/TRIGLYC

F. DIMENSION CLINICAL CHEMISTRY SYSTEM - URCA/URIC AC

G. DIMENSION VISTA SYSTEM - ENZYMATIC CREATININE ASSAY

H. DIMENSION EXL SYSTEM - ENZYMATIC CREATININE (EZCR) ASSAY

I. DIMENSION XPAND SYSTEM - ENZYMATIC CREATININE (EZCR) ASSAY

J. DIMENSION CLINICAL CHEMISTRY SYS. - AUTOMATED HDL

K. DIMENSION XPAND SYSTEM - AUTOMATED HDL CHOLESTEROL

L. DIMENSION EXL SYSTEM - AUTOMATED HDL CHOLESTEROL (AHDL) ASSAY

M. DIMENSION XPAND SYSTEM - TRIGLYCERIDES (TGL) ASSAY

N. DIMENSION XPAND SYSTEM - URIC ACID (URCA) ASSAY

O. DIMENSION EXL SYSTEM - TRIGLYCERIDES (TGL) ASSAY

P. DIMENSION EXL SYSTEM - URIC ACID (URCA) ASSAY

Reason

Siemens Healthcare Diagnostics has become aware of n-acetylcysteine (NAC) and metamizole (dipyrone) interference with Trinder and Trinder-like reaction assays. The Trinder reaction is a reaction where hydrogen peroxide is formed and subsequently reacts with a phenol derivative and aminoantipyrine in the presence of peroxidase to form a coloured quinone product.

Siemens has confirmed that falsely depressed results may occur on samples drawn from patients receiving n-acetylcysteine (NAC) or metamizole. NAC is the accepted antidote for acetaminophen toxicity and is justified in patients at significant risk for hepatotoxicity. Metamizole is an anti-inflammatory anti-pyretic drug banned in most countries because of the potential for nephrotoxicity.

The instructions for use (IFU) for the assays will be updated to indicate that: venipuncture should occur prior to n-acetylcysteine (NAC) or metamizole administration due to the potential for falsely depressed results.

Affected products

A. DIMENSION VISTA SYSTEM - HIGH DENSITY LIPOPROTEIN CHOLESTEROL ASSAY

Lot or serial number

All lots.

Model or catalog number

10464340

K3048A

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



B. DIMENSION VISTA SYSTEM - URIC ACID ASSAY

Lot or serial number

All lots.

Model or catalog number

K1077

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



C. DIMENSION VISTA SYSTEM - TRIGLYCERIDES ASSAY

Lot or serial number

All lots.

Model or catalog number

K2069

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



D. DIMENSION CLINICAL CHEMISTRY SYS - ENZYMATIC CREATININE ECRE FLEX REAG CART

Lot or serial number

All lots.

Model or catalog number

DF270B

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



E. DIMENSION CLINICAL CHEMISTRY SYSTEM - TRIG/TRIGLYC

Lot or serial number

All lots.

Model or catalog number

DF69A

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



F. DIMENSION CLINICAL CHEMISTRY SYSTEM - URCA/URIC AC

Lot or serial number

All lots.

Model or catalog number

DF77

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



G. DIMENSION VISTA SYSTEM - ENZYMATIC CREATININE ASSAY

Lot or serial number

All lots.

Model or catalog number

K1270A

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



H. DIMENSION EXL SYSTEM - ENZYMATIC CREATININE (EZCR) ASSAY

Lot or serial number

All lots.

Model or catalog number

10471520

DF270B

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



I. DIMENSION XPAND SYSTEM - ENZYMATIC CREATININE (EZCR) ASSAY

Lot or serial number

All lots.

Model or catalog number

DF270B

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



J. DIMENSION CLINICAL CHEMISTRY SYS. - AUTOMATED HDL

Lot or serial number

All lots.

Model or catalog number

10464332

DF48B

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



K. DIMENSION XPAND SYSTEM - AUTOMATED HDL CHOLESTEROL

Lot or serial number

All lots.

Model or catalog number

10464332

DF48B

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



L. DIMENSION EXL SYSTEM - AUTOMATED HDL CHOLESTEROL (AHDL) ASSAY

Lot or serial number

All lots.

Model or catalog number

10464332

DF48B

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



M. DIMENSION XPAND SYSTEM - TRIGLYCERIDES (TGL) ASSAY

Lot or serial number

All lots.

Model or catalog number

10444906

DF69A

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



N. DIMENSION XPAND SYSTEM - URIC ACID (URCA) ASSAY

Lot or serial number

All lots.

Model or catalog number

10444967

DF77

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



O. DIMENSION EXL SYSTEM - TRIGLYCERIDES (TGL) ASSAY

Lot or serial number

All lots.

Model or catalog number

10444906

DF69A

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES



P. DIMENSION EXL SYSTEM - URIC ACID (URCA) ASSAY

Lot or serial number

All lots.

Model or catalog number

10444967

DF77

Companies
Manufacturer

Siemens Healthcare Diagnostics Inc.

500 GBC DRIVE, MAILSTOP 514, P.O. BOX 6101

Newark

19714-6101

Alabama

UNITED STATES