This page has been archived on the Web

Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject to the Government of Canada Web Standards and has not been altered or updated since it was archived. Please contact us to request a format other than those available.

Consumer product recall

Scorpio and Absorbica Safety Lanyards

Starting date:
July 7, 2011
Posting date:
July 7, 2011
Type of communication:
Consumer Product Recall
Subcategory:
Sports/Fitness
Source of recall:
Health Canada
Audience:
General Public (GP)
Identification number:
RA-500002598

Recalled by Petzl America Inc.

Affected products

Scorpio and Absorbica Safety Lanyards

Product description

These recalled products are energy absorbing lanyards designed to be used in conjunction with a climbing harness to create a fall protection system.

The following table outlines the Scorpio model numbers and Universal Product Code (UPC) included in this recall.
Model Number UPC
L60 3342540053052
L60 CK 3342540054554
L60 2 3342540069466
L60 2CK 3342540069565
L60 H 3342540070448
L60 WL 3342540076723
The following table outlines the Absorbica model numbers and UPC included in this recall.
Model Number UPC
L57 3342540035058
L58 3342540035065
L58 MGO 3342540052727
L59 3342540035072
L59 MGO 3342540036529
L70150 I 3342540074453
L70150 IM 3342540074460
L70150 Y 3342540074477
L70150 YM 3342540074484

Hazard identified

Petzl has identified at least one energy absorbing system for each type of lanyard that appears to be missing one of the safety stitches on the attachment loop, which can cause the lanyard to disconnect from the climbing harness, posing a fall hazard to consumers.

There has been one report in France of the product failing due to the absence of a safety stitch, causing a fall and multiple fractures.

Health Canada has not received any reports of incidents or injuries related to the use of these lanyards.

Number sold

Approximately 2041 units of the recalled lanyards were sold at various stores across Canada.

Time period sold

The recalled products were sold from May 2002 until May 2011.

Place of origin

Manufactured in France.

Companies

Manufacturer

Petzl SAS

Crolles

FRANCE
Tel: 1-877-740-3826

Images (select thumbnail to enlarge - opens in a new window)



What you should do

Consumers should immediately stop using the recalled lanyards and contact PETZL for information regarding free inspection and replacement of any non-conforming products.

For more information, consumers may contact Petzl America, Inc. toll-free at 1-877-740-3826 between 8 a.m. and 5 p.m. MT Monday through Friday, by email at inspection.scorpio@petzl.com or visit the firm's website.