This page has been archived on the Web

Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject to the Government of Canada Web Standards and has not been altered or updated since it was archived. Please contact us to request a format other than those available.

Health professional risk communication

SAMSCA (tolvaptan) - Potential Risk of Liver Damage - For Health Professionals

Starting date:
February 27, 2013
Posting date:
March 1, 2013
Type of communication:
Dear Healthcare Professional Letter
Subcategory:
Drugs
Source of recall:
Health Canada
Issue:
Important Safety Information
Audience:
Healthcare Professionals
Identification number:
RA-23671

This is duplicated text of a letter from Otsuka Canada Pharmaceutical Inc. Contact the company for a copy of any references, attachments or enclosures.

Notice about Health Canada advisories

Health Canada Endorsed Important Safety Information on SAMSCA (tolvaptan)

February 27, 2013

Dear Health Care Professional,

Subject: SAMSCA® (tolvaptan) - New warning regarding a potential risk of liver injury.

Otsuka Canada Pharmaceutical Inc. (Otsuka) in consultation with Health Canada would like to inform you of a risk of liver injury associated with the use of SAMSCA® (tolvaptan).

SAMSCA® (15-60 mg) is indicated for the treatment of clinically important, non-hypovolemic hyponatremia (e.g., serum sodium < 130 mEq/L, or symptomatic hyponatraemia).

  • SAMSCA® (tolvaptan) has the potential to cause irreversible and potentially fatal liver injury. During a large clinical trial (TEMPO 3:4)Footnote 1 in about 1400 patients with Autosomal Dominant Polycystic Kidney Disease (ADPKD), three patients out of the 958 treated with tolvaptan (60-120 mg daily), developed serious liver injuries (ALT > 3x ULN with concomitant Total Bilirubin > 2X ULN). All three patients improved following discontinuation of treatment. SAMSCA® is not approved for the treatment of ADPKD.
  • If a patient reports symptoms that may indicate liver injury, including fatigue, anorexia, right upper abdominal discomfort, dark urine or jaundice, liver tests should be performed promptly. SAMSCA® should be immediately discontinued and appropriate treatment initiated. Investigations should be performed to determine the cause.  SAMSCA® should not be re-initiated in patients unless the cause for the observed liver injury is definitively established to be unrelated to treatment with SAMSCA®.
  • The ability to recover from liver injury may be impaired in patients with hyponatremia in the setting of underlying liver disease, including cirrhosis. Limiting the duration of SAMSCA® therapy may reduce the risk of developing liver injury.

During the TEMPO 3:4 trialFootnote 1 (a double-blind, 3-year, placebo-controlled trial in ADPKD patients and its open-label extension), tolvaptan was associated with an increased incidence of significant elevations of ALT (>3x ULN) compared to placebo. Specifically, 4.4% (42/958) of ADPKD patients on tolvaptan and 1.0% (5/484) of patients on placebo exhibited elevations of ALT greater than 3x ULN. Most of the liver enzyme abnormalities were observed during the first 18 months of therapy.  The elevations gradually improved after discontinuation of tolvaptan. In this trial, the maximum daily dose of tolvaptan administered (90 mg in the morning and 30 mg in the afternoon) was higher than the maximum 60 mg daily dose approved for the treatment of hyponatremia.

In other clinical trials of SAMSCA®, including the trials supporting the approved indication, liver damage has not been reportedFootnote 2,Footnote 3. However, these data are not adequate to exclude the possibility that these patients are at an increased risk for irreversible and potentially fatal liver injury. Limiting the duration of SAMSCA® therapy may reduce the risk of developing liver injury.

The Canadian Product Monograph is currently being updated to reflect on this new safety information regarding the use of SAMSCA®.

Managing marketed health product-related adverse reactions depends on health care professionals and consumers reporting them. Reporting rates determined on the basis of spontaneously reported post-marketing adverse reactions are generally presumed to underestimate the risks associated with health product treatments. Any case of serious hepatic injury or other serious or unexpected adverse reactions in patients receiving SAMSCA® (tolvaptan) should be reported to Otsuka Canada Pharmaceutical Inc. or Health Canada at the following addresses:

Otsuka Canada Pharmaceutical Inc.

2250 Alfred Nobel Blvd.

Saint-Laurent, Quebec

H4S 2C9

Phone: 1-877-341-9245

Fax: 1-905-689-1465

To correct your mailing address or fax number, contact Otsuka Canada Pharmaceutical Inc.

You can report any suspected adverse reactions associated with the use of health products to Health Canada by:

  • Calling toll-free at 1-866-234-2345; or
  • Visiting MedEffect Canada's Web page on Adverse Reaction Reporting for information on how to report online, by mail or by fax.

For other health product inquiries related to this communication, please contact Health Canada at:

Marketed Health Products Directorate

E-mail: mhpd_dpsc.public@hc-sc.gc.ca

Telephone: 613-954-6522

Fax: 613-952-7738

If you have any questions or need additional information about SAMSCA®, please contact Otsuka Medical Information at 1-877-341-9245.

Otsuka is committed to the highest ethical and safety standards and continues to monitor liver safety in all tolvaptan clinical trials and in post marketing reports.

Sincerely,

original signed by

Otsuka Canada Pharmaceutical Inc.

per:

Khalid Mezzi, MD

Director, Medical Affairs

®Samsca is a registered trademark of Otsuka Pharmaceutical Co., Ltd., used under license by Otsuka Canada Pharmaceutical Inc.

References:

Footnotes

Footnote 1

Torres VE, Chapman AB, Devuyst O, Gansevoort RT, Grantham JJ, Higashihara E, Perrone RD, Krasa HB, Ouyang J, Czerwiec FS; the TEMPO 3:4 Trial Investigators. Tolvaptan in Patients with Autosomal Dominant Polycystic Kidney Disease. N Engl J Med. 2012 Nov 3.

Return to footnote 1 referrer

Footnote 2

Schrier RW, Gross P, Gheorghiade M, Berl T, Verbalis JG, Czerwiec FS, Orlandi C; SALT Investigators. Tolvaptan, a selective oral vasopressin V2- receptor antagonist, for hyponatremia. N Engl J Med. 2006 Nov 16;355(20):2099-112. Epub 2006 Nov 14.

Return to footnote 2 referrer

Footnote 3

Berl T, Quittnat-Pelletier F, Verbalis JG, Schrier RW, Bichet DG, Ouyang J, Czerwiec FS; SALTWATER Investigators. Oral tolvaptan is safe and effective in chronic hyponatremia. J Am Soc Nephrol. 2010 Apr;21(4):705-12. Epub 2010 Feb 25.

Return to footnote 3 referrer