Philips IntelliVue Patient Monitors
Summary
Contact the manufacturer if you require additional information.
Affected products
Affected products |
Lot or serial number |
Model or catalogue number |
|---|---|---|
IntelliVue MP40 Patient Monitor System - Main Unit |
More than 10 numbers, contact manufacturer. |
M8003A |
IntelliVue MX400 Patient Monitor |
More than 10 numbers, contact manufacturer. |
866060 |
IntelliVue MX850 Patient Monitor |
More than 10 numbers, contact manufacturer. |
866470 |
IntelliVue MP70 Patient Monitor System - Main Unit |
More than 10 numbers, contact manufacturer. |
M8007A |
IntelliVue MX Patient Monitor System - Main Unit |
More than 10 numbers, contact manufacturer. |
MX700 |
IntelliVue MP60 Patient Monitor System - Main Unit |
More than 10 numbers, contact manufacturer. |
M8005A |
IntelliVue MP20 Patient Monitor System |
More than 10 numbers, contact manufacturer. |
M8001A |
IntelliVue MP5 Patient Monitor System - Main Unit |
More than 10 numbers, contact manufacturer. |
M8105A |
IntelliVue X2 Multi-Measurement Module - Main Unit |
More than 10 numbers, contact manufacturer. |
M3002A |
IntelliVue MP90 Patient Monitor System - Main Unit |
More than 10 numbers, contact manufacturer. |
M8010A |
IntelliVue MP30 Patient Monitor System |
More than 10 numbers, contact manufacturer. |
M8002A |
IntelliVue MP80 Patient Monitor System - Main Unit |
More than 10 numbers, contact manufacturer. |
M8008A |
IntelliVue MP50 Patient Monitor System - Main Unit |
More than 10 numbers, contact manufacturer. |
M8004A |
IntelliVue MP2 Patient Monitor - Main Unit |
More than 10 numbers, contact manufacturer. |
M8102A |
IntelliVue MX550 Patient Monitor |
More than 10 numbers, contact manufacturer. |
866066 |
IntelliVue MX750 Patient Monitor |
More than 10 numbers, contact manufacturer. |
866471 |
IntelliVue MX500 Patient Monitor |
More than 10 numbers, contact manufacturer. |
866064 |
IntelliVue Patient Monitor |
More than 10 numbers, contact manufacturer. |
866062 |
IntelliVue MX Patient Monitor System - Main Unit |
More than 10 numbers, contact manufacturer. |
MX800 |
IntelliVue MX100 Patient Monitor |
More than 10 numbers, contact manufacturer. |
867033 |
X3 Multi-Measurement Module |
More than 10 numbers, contact manufacturer. |
867030 |
Issue
Philips IntelliVue patient monitors provide a feature for pausing all alarms for a configured timeframe or for switching all alarms off for an infinite period until they are switched back on by the user.
The infinite alarms off feature is an important functionality in specific clinical environments such as the operating room, cath lab or during resuscitations to reduce the audible alarms which may present unnecessary distractions during closely monitored procedures or interventions.
Philips has received complaints that the IntelliVue monitors did not alarm. In some cases, these complaints alleged delayed patient treatment due to the monitors not alarming; and, in some cases, there were reports of severe patient harm or death. It was determined that in these instances the alarms had been switched off for an infinite period, and the user may have been unaware that the alarms were off.
Additional information
Details
| Philips Medizin Systeme Boblingen Gmbh |
| Hewlett-Packard Strasse 2, Boblingen, Germany, 71034 |