Health product recall

Palindrome/Mahurkar Chronic Catheter

Brand(s)
Last updated

Summary

Product
Palindrome/Mahurkar Chronic Catheter
Issue
Medical devices - Performance
What to do

Contact the manufacturer if you require additional information.

Audience
Healthcare

Affected products

Affected products

Lot or serial number

Model or catalog number

Palindrome Precision Si Chronic Catheter

More than 10 numbers, contact manufacturer.

8888145063P
8888145064P
8888145062P
8888119368P
8888123408P

Palindrome Precision Si Chronic Catheter

More than 10 numbers, contact manufacturer.

8888119368
8888123408

Palindrome Precision Chronic Catheter

More than 10 numbers, contact manufacturer.

8888133504P
8888123400P
8888128450P
8888119360P
8888119364P
8888128454P
8888123404P

Palindrome Precision Chronic Catheter

More than 10 numbers, contact manufacturer.

8888123400
8888123410
8888128450
8888119360
8888119364
8888119370
8888128454
8888133504
8888123404
8888128460

Mahurkar Chronic Carbothane Catheters

More than 10 numbers, contact manufacturer.

8888145028
8888145027

Mahurkar Chronic Carbothane Catheters

More than 10 numbers, contact manufacturer.

8888145251
8888145252
8888145254
8888145253

Palindrome Precision Hsi Chronic Catheter

More than 10 numbers, contact manufacturer.

8888133509P
8888119369P
8888145049P
8888145048P
8888145057P

Palindrome Precision Hsi Chronic Catheter

More than 10 numbers, contact manufacturer.

8888133509
8888119369

Palindrome Precision Chronic Catheter

More than 10 numbers, contact manufacturer.

8888145060
8888145059
8888145061
8888145058

Palindrome Precision H Chronic Catheter

More than 10 numbers, contact manufacturer.

8888145046
8888145043
8888145045
8888145069
8888145044

Palindrome Precision Chronic Catheter

More than 10 numbers, contact manufacturer.

8888128460P
8888123410P
8888119370P
8888145058P
8888145061P
8888145059P

Mahurkar Chronic Carbothane Catheters

More than 10 numbers, contact manufacturer.

8888119362

Palindrome Precision Chronic Catheter

More than 10 numbers, contact manufacturer.

8888145014P
8888145039P
8888145042P
8888145017P
8888145015P
8888145018P
8888145016P
8888145040P
8888145041P
8888146044P

Palindrome Precision Chronic Catheter

More than 10 numbers, contact manufacturer.

8888119365P
8888145046P
8888145043P
8888145045P
8888145044P
8888128455P
8888123405P
8888145069P

Palindrome Precision Hsi Chronic Catheter

More than 10 numbers, contact manufacturer.

8888145049
8888145057
8888145048

Palindrome Precision Si Chronic Catheter

More than 10 numbers, contact manufacturer.

8888145017
8888145039
8888145064
8888145063
8888145018
8888145041
8888145014
8888145016
8888145040
8888145042
8888145015
8888145062

Palindrome Precision H Chronic Catheter

More than 10 numbers, contact manufacturer.

8888128455
8888119365
8888123405

Mahurkar Chronic Carbothane Catheters

More than 10 numbers, contact manufacturer.

8888145003
8888145002
8888145004
8888145001

Mahurkar Chronic Carbothane Catheters

More than 10 numbers, contact manufacturer.

8888119385
8888133535
8888123435
8888128485

Issue

Medtronic has identified a potential leaking condition within the hub of specific chronic hemodialysis catheters. Flushing one extension tube may result in unanticipated fluid return through the adjacent extension tube (in addition to the anticipated flow of fluid through the distal tip of the catheter). The condition is the result of an inter-lumen void formed in the hub component of the catheter during the manufacturing process. during use, this observed condition could translate to cross-communication of the blood circuit.

Recall start date: June 9, 2022

Additional information

Details
Original published date:
Alert / recall type
Health product recall
Category
Health products - Medical devices - General hospital and personal use
Companies

Covidien LLC

15 Hampshire Street, Mansfield, Massachusetts, United States, 02048

Published by
Health Canada
Audience
Healthcare
Recall class
Type II
Identification number
RA-64286

Get notified

Receive emails about new and updated recall and safety alerts.

Subscribe