This page has been archived on the Web
Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject to the Government of Canada Web Standards and has not been altered or updated since it was archived. Please contact us to request a format other than those available.
Invacare Power Wheelchairs (2015-01-09)
- Starting date:
- January 9, 2015
- Posting date:
- January 23, 2015
- Type of communication:
- Medical Device Recall
- Subcategory:
- Medical Device
- Hazard classification:
- Type II
- Source of recall:
- Health Canada
- Issue:
- Medical Devices
- Audience:
- General Public, Healthcare Professionals, Hospitals
- Identification number:
- RA-43455
Recalled Products
A) TDX SR series Power Wheelchairs
B) FDX series Power Wheelchairs
C) Storm series Power Wheelchairs
D) TDX SP Power Wheelchairs
Reason
Invacare has recently identified a potential wiring pinch point involving Invacare FDX, TDX series and storm series power wheelchairs with 20"-24" width configurations with formula CG recline seating system (i.e. tilt/recline, tilt/recline/elevate, or recline only) and a conventional style back. There is a possibility that if the slack in the wires is not routed and secured correctly, and with flexing of the back pan under the user's weight, the headrest knob or clamp bracket may pinch, damage or cut the wire creating a hazard. Smoking, sparking, burning or fire may occur if any wire in this area is repetitively pinched at the same location over a period of time. Not all impacted chairs are expected to have slack in the wiring that is not routed and secured correctly.
Affected products
A) TDX SR series Power Wheelchairs
Lot or serial number
Contact manufacturer.
Model or catalog number
TDXSR-CG
TDXSR-CG-HD
TDXSR-MCG
TDXSR-MCG-HD
TDXSRSEAT
Companies
- Manufacturer
-
Invacare Corp.
One Invacare Way
Elyria
44036
Ohio
UNITED STATES
B) FDX series Power Wheelchairs
Lot or serial number
Contact manufacturer.
Model or catalog number
FDX-CG
FDX-MCG
Companies
- Manufacturer
-
Invacare Corp.
One Invacare Way
Elyria
44036
Ohio
UNITED STATES
C) Storm series Power Wheelchairs
Lot or serial number
Contact manufacturer.
Model or catalog number
3GAR-CG
3GRX-CG
3GSEAT-CG
3GTQ-CG
3GTQ-MCG
3GTQ3-CG
3GTQ3-MCG
Companies
- Manufacturer
-
Invacare Corp.
One Invacare Way
Elyria
44036
Ohio
UNITED STATES
D) TDX SP Power Wheelchairs
Lot or serial number
Contact manufacturer.
Model or catalog number
TDXSP-CG
TDXSP-CG-GT
TDXSP-MCG
TDXSP-MCG-GT
TDXSPSEAT
Companies
- Manufacturer
-
Invacare Corp.
One Invacare Way
Elyria
44036
Ohio
UNITED STATES