Health professional risk communication

Important Information About the Risk of Dosing Error for Tamiflu (oseltamivir phosphate) Powder for Oral Suspension (12 mg/mL) - For Health Professionals

Starting date:
October 13, 2009
Posting date:
October 15, 2009
Type of communication:
Dear Healthcare Professional Letter
Subcategory:
Drugs, Affects children, pregnant or breast feeding women
Source of recall:
Health Canada
Audience:
Healthcare Professionals
Identification number:
RA-170002158

This is duplicated text of a letter from Hoffmann-La Roche Limited. Contact the company for a copy of any references, attachments or enclosures.

Notice about Health Canada advisories

Health Canada Endorsed Important Safety Information on TAMIFLU (oseltamivir phosphate) Suspension

October 13, 2009

Subject: Important information about risk of dosing error for TAMIFLU® (oseltamivir phosphate) Powder for Oral Suspension (12 mg/mL).

Dear Health Care Professional,

Hoffmann-La Roche Limited, in consultation with Health Canada, would like to inform you of important dosing and administration information regarding the use of TAMIFLU® (oseltamivir phosphate) Powder for Oral Suspension.

TAMIFLU is a viral neuraminidase inhibitor authorized for sale in Canada for use in the treatment and prevention of uncomplicated acute illness due to influenza infection in adults and children above the age of 1 who have been symptomatic for no more than 2 days or have come in close contact with an infected individual (the index case). Health Canada has also issued an Interim OrderFootnote 1 in July 2009 expanding use of TAMIFLU as a treatment or prophylaxis for children less than 1 year of age for infection caused by the pandemic H1N1 2009 virus.

Healthcare Providers should note the following information regarding the use of TAMIFLU:

  • When dispensing commercially manufactured TAMIFLU Powder for Oral Suspension (12 mg/mL), pharmacists should ensure that the units of measure on the prescription instructions match the dosing device provided (e.g. a device graduated in mg for a prescription in mg).
  • In Canada, the oral dosing dispenser provided with TAMIFLU Powder for Oral Suspension is marked with 30 mg, 45 mg, and 60 mg graduations, rather than graduations in milliliters (mL) or teaspoons (tsp). The recommended dosing instructions for adults and children are also provided in milligrams.

There have been reported cases, in the US, where the units of measure in the instructions on the pharmacy prescription label were provided in milliliters (mL) or teaspoons, while the dosing device provided with the prescription was graduated in milligrams (mg). This has led to patient or caregiver confusion and dosing errors.

There have been no reports in Canada suggesting dosing errors associated with the use of TAMIFLU Powder for Oral Suspension.

When dispensing commercially manufactured TAMIFLU Powder for Oral Suspension (12 mg/mL), pharmacists should ensure the units of measure on the prescription instructions match the dosing device.

  • If prescription instructions specify administration using milligrams (mg), as per the approved dosing recommendations, then the oral dosing dispenser included in the TAMIFLU product package should be provided to patients and the pharmacy prescription label should provide dosing instructions in milligrams (mg).
  • If prescription instructions specify administration using milliliters (mL) or teaspoons (tsp), then the oral dosing dispenser included in the TAMIFLU product package should be removed and replaced with an appropriate measuring device, such as an oral syringe.

Currently, the supply of TAMIFLU Powder for Oral Suspension is very limited and will continue to be so throughout this year. We would like to remind you that should the oral suspension not be readily available, the package insert provides guidance for emergency compounding of capsules to produce liquid suspensions (15 mg/mL) for administration to children or adults with difficulty swallowing capsules. Note: This compounding procedure results in a 15 mg/mL suspension, which is different from the commercially available TAMIFLU for Oral Suspension, which has a concentration of 12 mg/mL.

Dose recommendations according to the TAMIFLU Canadian product monographFootnote 2 for patients greater than 1 year of age and the Health Canada Interim OrderFootnote 1,Footnote 3 dosing instructions for patients less than 1 year of age are summarized in the tables below. Please note that the last column in the tables refers to the commercially available oral suspension, and not the one obtained after compounding. A compounded suspension will have a different concentration and a different final volume.

Table 1: Treatment of influenza - Each dose is given twice daily for 5 days
In patients 1 year of age or older
Body Weight in kg Body Weight in lbs Recommended

Dose for 5 days
Quantity of TAMIFLU for

Oral Suspension to

Withdraw for Each Dose
≤15 kg ≤33 lbs 30 mg twice daily 2.5 mL
> 15 kg to 23 kg > 33 lbs to 51 bs 45 mg twice daily 3.8 mL
> 23 kg to 40 kg > 51 lbs to 88 bs 60 mg twice daily 5.0 mL
> 40 kg > 88 lbs 75 mg twice daily 6.2 mL
In patients less than 1 year of age
Based on weight (recommended): 2 mg / kg BID × 5 days

If weight is not available:
  • 0 - < 3 months: 12 mg twice daily for 5 days
  • 3 - < 6 months: 20 mg twice daily for 5 days
  • 6 - < 12 months: 25 mg twice daily for 5 days
Table 2: Prophylaxis of influenza - Each dose is given once a day for 10 days
In patients 1 year of age or older
Body Weight in kg Body Weight in lbs Recommended

Dose for at least 10 days
Quantity of TAMIFLU for

Oral Suspension to

Withdraw

for Each Dose
≤15 kg ≤33 lbs 30 mg once daily 2.5 mL
> 15 kg to 23 kg > 33 lbs to 51 bs 45 mg once daily 3.8 mL
> 23 kg to 40 kg > 51 lbs to 88 bs 60 mg once daily 5.0 mL
> 40 kg > 88 l bs 75 mg once daily 6.2 mL
In patients less than 1 year of age
Based on weight (recommended): 2 mg / kg once a day × 10 days

If weight is not available:
  • 0 - < 3 months: Not recommended for use at this time
  • 3 - < 6 months: 20 mg once a day x 10 days
  • 6 - < 12 months: 25 mg once a day x 10 days

We encourage you to become familiar with these dosing instructions. For additional information regarding compounding from capsules as well as emergency compounding, please refer to the product monographFootnote 2 . Should you have any questions or require additional information regarding the use of TAMIFLU, please contact the Drug Information Department at Hoffman-La Roche Limited at 1-888-762-4388 from 8:30 a.m. to 4:30 p.m. Monday to Friday Eastern Standard Time.

Managing marketed health product-related adverse reactions depends on health care professionals and consumers reporting them. Reporting rates determined on the basis of spontaneously reported postmarketing adverse reactions are generally presumed to underestimate the risks associated with health product treatments. Any case of serious or unexpected adverse reactions in patients receiving TAMIFLU® Tablets and Oral Solution should be reported to Hoffmann-La Roche Limited or Health Canada at the following addresses:

Hoffmann-La Roche Limited

Drug Safety Department

2455 Meadowpine Boulevard

Mississauga, Ontario, L5N 6L7

or call toll free at: 1-888-762-4388

or Fax at: 905-542-5864

or Email: mississauga.drug_safety@roche.com

Any suspected adverse reaction can also be reported to:

Canada Vigilance Program

Marketed Health Products Directorate

HEALTH CANADA

Address Locator: 0701C

Ottawa, Ontario, K1A 0K9

Telephone: 613-957-0337 or Fax: 613-957-0335

To report an Adverse Reaction, consumers and health professionals may call toll free:

Telephone: 866-234-2345

Fax: 866-678-6789

CanadaVigilance@hc-sc.gc.ca

The Adverse Reaction Reporting Form and the Adverse Reaction Guidelines can be found on the Health Canada web site or in The Canadian Compendium of Pharmaceuticals and Specialties.

For other inquiries related to this communication, please contact Health Canada at:

Marketed Health Product Directorate (MHPD)

E-mail: mhpd_dpsc@hc-sc.gc.ca

Telephone: 613-954-6522

Fax: 613-952-7738

Sincerely,

original signed by

Lorenzo Biondi,

Vice President, Medical and Regulatory Affairs

Hoffmann-La Roche Limited

References:

References:

Footnote 1

Interim Order Respecting the Sale of Oseltamivir Phosphate - Expanded use for Children under One Year of Age. Parliament of Canada. July 20, 2009. Accessed: 2009-09-29.

Return to footnote 1 referrer

Footnote 2

Tamiflu, Approved Product Monograph. Hoffmann-La Roche Limited, Mississauga, Ontario. Revised July 10, 2009.

Return to footnote 2 referrer

Footnote 3

Interim Guidance for emergency use of oseltamivir (Tamiflu®) In children under one year of age in the context of 2009 (H1N1) pandemic. Public Health Agency of Canada. Modified: 2009-07-20. Accessed: 2009-09-29.

Return to footnote 3 referrer