This page has been archived on the Web
Information identified as archived is provided for reference, research or recordkeeping purposes. It is not subject to the Government of Canada Web Standards and has not been altered or updated since it was archived. Please contact us to request a format other than those available.
For Health Professionals - Association of acute renal failure (severe kidney problems) and reports of cytopenias (low blood cell counts) with Exjade (deferasirox)
- Starting date:
- March 9, 2007
- Posting date:
- March 19, 2007
- Type of communication:
- Dear Healthcare Professional Letter
- Subcategory:
- Drugs
- Source of recall:
- Health Canada
- Audience:
- Healthcare Professionals
- Identification number:
- RA-170001585
This is duplicated text of a letter from Novartis Pharmaceuticals Canada Inc.
Contact the company for a copy of any references, attachments or enclosures.
Notice about Health Canada advisories
Health Canada Endorsed Important Safety Information on ExjadeFootnote * (deferasirox)
March 9, 2007
Dear Health Care Professional:
Subject: Acute renal failure associated with EXJADEFootnote * (deferasirox) Reports of cytopenias with EXJADEFootnote * (deferasirox)
Following discussions with Health Canada, Novartis wishes to provide you with updated safety information regarding reports of acute renal failure and peripheral blood cytopenias with EXJADEFootnote *.
EXJADEFootnote * (deferasirox) is indicated in the management of chronic iron overload in patients with transfusion-dependent anemias aged 6 years or older. EXJADEFootnote * is also indicated in the management of chronic iron overload in patients with transfusion-dependent anemias aged two to five who cannot be adequately treated with deferoxamine.
Therapy with EXJADEFootnote * should be initiated and maintained by physicians experienced in the treatment of chronic iron overload due to blood transfusions.
- Cases of acute renal failure (some with fatal outcome) have been reported following the post-marketing use of EXJADEFootnote *. For the fatal cases, it is impossible to completely exclude a contributory role of EXJADEFootnote * to the renal impairment, although the fatalities in these critically ill patients could be attributable to other underlying diseases. The fact that there was an improvement after stopping the treatment in most of the cases with non-fatal acute renal failure is suggestive of a contributory role of EXJADEFootnote * to these cases.
- Serum creatinine should be assessed twice before initiating therapy. Weekly monitoring of serum creatinine is recommended in the first month after initiation or modification of therapy, and monthly thereafter. Tests for proteinuria should be performed monthly. Care should be taken to maintain adequate hydration in patients.
- There have been post-marketing reports (both spontaneous and from clinical trials) of cytopenias in patients treated with EXJADEFootnote *. Most of these patients had pre-existing hematologic disorders that are frequently associated with bone marrow failure. The relationship of these episodes to treatment with EXJADEFootnote * is unknown.
EXJADEFootnote * has not been studied in patients with renal impairment. EXJADE-treated patients experienced dose-dependent increases in serum creatinine. Increases in creatinine that were > 33% at ≥ 2 consecutive post baseline visits occurred at a greater frequency in EXJADE-treated patients compared to deferoxamine-treated patients (38% vs. 14%, respectively) in a clinical trial. In clinical trials, under the dose adjustment instructions, dose reduction was required in one third of patients showing serum creatinine increase. In most patients undergoing dose reductions serum creatinine levels did not return to baseline; in 60% of patients undergoing dose reduction, serum creatinine remained elevated at > 33% without progression.
In line with standard clinical management of cytopenias, blood counts should be monitored regularly. Interruption of treatment with EXJADEFootnote * should be considered in patients who develop unexplained cytopenia.
Managing marketed health product related adverse reactions depends on health care professionals and consumers reporting them, in addition to reports collected from clinical trials. Reporting rates determined on the basis of spontaneously reported post marketing adverse reactions are generally presumed to underestimate the risks associated with health product treatments. Any serious or unexpected adverse events in patients receiving EXJADEFootnote * should be reported to Novartis or Health Canada at the following addresses:
Novartis Pharmaceuticals Canada Inc.
385 Bouchard Blvd.
Dorval, (QC) H9S 1A9
Phone:1-800-363-8883 (Medical information)
Any suspected adverse reaction can also be reported to:
Canadian Adverse Drug Reaction Monitoring Program (CADRMP)
Marketed Health Products Directorate
Health Canada
Address Locator: 0701C
Ottawa, Ontario, K1A 0K9
Tel: (613) 957-0337 or Fax: (613) 957-0335
To report an Adverse Reaction, consumers and health professionals may call toll free:
Tel: 866 234-2345
Fax: 866 678-6789
cadrmp@hc-sc.gc.ca
The AR Reporting Form and the AR Guidelines can be found on the Health Canada web site or in The Canadian Compendium of Pharmaceuticals and Specialties.
For other inquiries related to this communication, please contact Health Canada at:
Marketed Health Products Directorate (MHPD)
E-mail: MHPD_DPSC@hc-sc.gc.ca
Tel: (613) 954-6522
Fax: (613) 952-7738
Your professional commitment in this regard has an important role in protecting the well being of your patients by contributing to early signal detection and informed drug use.
Should you have medical enquiries regarding EXJADEFootnote *, please contact our Medical Information Department at 1-800-363-8883.
For more information please consult the EXJADEFootnote * Prescribing Information and Consumer Information on our Website (http://www.novartis.ca).
Sincerely,
original signed by
Vice-President
Regulatory Affairs
Chief Scientific Officer and Senior Vice-President Clinical and Regulatory Affairs
Footnotes
- Footnote 1
-
EXJADE is a registered trademark.